SERVICE INFORMATION
Product:
DW95
Date:
98-03-13
TOPIC:
CONTROL UNIT FAILURE ANALYSIS
To prevent repeated exchanges of control units due to failures in auxiliary components (circulation pumps,
inlet valves, etc.), a simple check on the control unit should be done to determine what cause the failure.
If any of the control unit components listed below or the conductive pattern (copper foil on the soldering
side) near these components are damaged, most likely the external component caused the failure and
should be ohm-measured. In the case of short-circuits, the components should be exchanged along with
the control unit.
External Component
Associated Output Components
Heater
K1, PF2
Drain pump
K2, P1 5
Circulation pump
K3, P1 3
Inlet valve 1
Q13, R36, R52, D22, D24, P1 7
Inlet valve 2
Q6, R43, R55, D26, D27, P1 8
Combi-dispenser
Q12, R50, R58, D21, D23, P2 3
Fan and wax motor
Q16, R46, R56, D18, D19, P3 3
Interior light
P4 3 (after 9740, the lamp is not connected to the control unit.)
K=Relay
Q=Triac
R=Resistor
D=Diode
P=Connector
Note:
Once the was motor has dried out, it is not possible to measure for faults. Remove the wax
motor and check for burn marks. For complete certainty, replace the wax motor.
Summary of Contents for D1976
Page 9: ...Model D1976 DW 955 Page Date 2000 06 9 This page intentionally blank ...
Page 10: ...Model D1976 DW 955 Date 2000 06 Page 10 CASING AND RELATED PARTS 9 11 1 2 3 4 5 6 7 8 10 ...
Page 14: ...Model D1976 DW 955 Date 2000 06 Page 14 DOOR 1 2 3 4 5 6 7 8 9 15 13 11 12 10 17 16 14 ...
Page 20: ...Model D1976 DW 955 Date 2000 06 Page 20 INTERIOR LIGHT 1 2 3 4 5 6 7 8 9 10 ...
Page 22: ......
Page 23: ......