PROGRAMS
EXTENDING FAN COOLING TIME
To extend the fan cooling time,
press S1 five times then press
one of the following:
S5
for 30 extra minutes
S4
for normal fan cooling time
SETTING AN EXTRA RINSE
To add an extra rinse to the Pots and Pans, Super, Normal and Light wash programs,
press S2 five
times then press
one of the following:
S5
for an extra rinse
S4
for the normal number of rinses
SETTING CHILD-SAFE START FUNCTION
The start function can be reprogrammed so that the Start button must be pressed in for 3 seconds to
start the programs. To do this,
press S4 five times then press
one of the following:
S5
to get a prolonged start function or
S4
to get a normal start function.
SETTING PUMP-OUT TIME
If it's necessary to reprogram the pump-out time, you can do so by
pressing S3 five times then pressing
one of the following:
Press:
to get an outlet time of:
S3
20 seconds
S4
25 seconds (factory setting)
S5
35 seconds
S6
45 seconds
S7
85 seconds
SETTING INLET TIME
You can reprogram the inlet time on level controlled and time controlled inlets. To do this,
press S5 five
times then press
one of the following:
Press:
to get an inlet time of:
S3
45 seconds (factory setting)
S4
56 seconds
S5
68 seconds
S6
90 seconds
S7
113 seconds
S8
180 seconds
S = Pushbutton switch L = Indicator light
Summary of Contents for D1976
Page 9: ...Model D1976 DW 955 Page Date 2000 06 9 This page intentionally blank ...
Page 10: ...Model D1976 DW 955 Date 2000 06 Page 10 CASING AND RELATED PARTS 9 11 1 2 3 4 5 6 7 8 10 ...
Page 14: ...Model D1976 DW 955 Date 2000 06 Page 14 DOOR 1 2 3 4 5 6 7 8 9 15 13 11 12 10 17 16 14 ...
Page 20: ...Model D1976 DW 955 Date 2000 06 Page 20 INTERIOR LIGHT 1 2 3 4 5 6 7 8 9 10 ...
Page 22: ......
Page 23: ......