EN 35
INSTALLATION
General
This appliance should only be connected by a registered installer! The electrical
connection must comply with national and local regulations.
Warning! This appliance must be earthed at all times.
• Installation, maintenance, or repairs should only be carried out by professionals who are
authorised by the manufacturer, as failure to do so will void the guarantee.
• The device should be disconnected from the mains prior to installation, maintenance or
repairs. The device is only disconnected from the electric power if:
▷
The main switch of the domestic electrical system is switched Off, the fuse of the
domestic electrical system has been completely removed, or the plug has been pulled
out of the socket.
• Faulty parts may only be replaced by original ASKO parts. Only those parts are guaranteed
by ASKO to meet the safety requirements.
• To avoid dangerous situations resulting from any damage to the connecting cable, this
should only be replaced by the manufacturer, the manufacturer’s service organisation or
suitably qualified persons.
Electrical connection
230 V~ - 50 Hz
400 V~ - 50 Hz (400 V models only)
• Wall socket and plug must be accessible at all times.
• Make sure that the cable does not come into contact with parts of the oven that may
become hot.
• If you want to make a fixed connection, ensure that a multi-pole switch with a distance
between contacts of 3 mm is installed in the supply cable.
• Do not use a multiple socket or an extension lead to connect the device to the electrical
mains. Safe use of the device cannot be guaranteed with such accessories.
Consult the wiring diagrams on the back of the appliance. Also consult chapter
‘Setting the maximum total hob power’. Make the required connections on the
connecting block.
This appliance can be connected in accordance with a
3 phases connection (3 N~ 380 V - 415 V / 50 Hz - 3 x 16 A).