44
Operation - 4
3) Open “Filter Service Cover” and confirm that idle fan turning direction is same as
the fan direction. (As Standard all ASKAYNAK fans shall turn counter-clockwise
from fan inlet port view!)
4a) If Fan is rotating in the correct direction, close “Filter Service Cover”. Filter
unit is ready to operate!
4b) If Fan is rotating in false direction;
- Cut off electrical connection.
- Interchange two phase connection with each other at the plug!
- Fan will rotate at the correct direction!
COMMISSIONING:
Filter unit can be commissioned after extraction arm assembly and Fan rotation
direction control by the main switch!
- If Filter unit is operated before, there could be risk of
“Dust Hazard.”
Use protective equipment (mask, glass, glove and clothing),
while implementing any operation, to prevent direct contact
with dust.
- Turning Impeller Hazard!
Do not put your hands or fingers near or inside near fan
inlet port.
US
E
R
G
UI
D
E