-4-
Model No.
Dimensions inch (mm)
Weight
lbs. (kg.)
Type of
Burner
No. of
Burners
Ignition
Standard
Heating
Space Square
Feet / (m
2
)
DVAG11N
DVAG11L
Height:
Width:
Depth:
20 (508 mm)
17.36 (441 mm)
6.61 (168 mm)
28 (12.7 kg)
Atmospheric
1
Piezo-electric ignitor
200 (18.6 m
2
)
DVAG17N
DVAG17L
Height:
Width:
Depth:
20 (508 mm)
27.36 (695 mm)
6.61 (168 mm)
43 (19.5 kg)
Atmospheric
1
Piezo-electric ignitor
275 (25.6 m
2
)
DVAG30N
DVAG30L
Height:
Width:
Depth:
26.30 (668 mm)
32.28 (820 mm)
8.74 (222 mm)
62.2 (28.2 kg)
Atmospheric
1
Piezo-electric ignitor
425 (39.5 m
2
)
Figure 3
NOTE: A qualified service person must install the heater. Follow all local codes. CHECK GAS TYPE! Use only the
type of gas indicated on the rating plate.
Model DVAG11
Model DVAG30
Model DVAG17
17.36" (441 mm)
20"
(508 mm)
6.61"
(168 mm)
20"
(508 mm)
27.36" (695 mm)
6.61"
(168 mm)
26.30"
(668 mm)
32.28" (820 mm)
8.74"
(222 mm)
Installation
CEILING
36”
(914 mm) Min.
6”
(152 mm) Min.
6”
(152 mm) Min.
FLOOR
INSTALLATION ITEMS
Before installing heater, make sure you have the items listed below.
•
Piping (check local codes)
•
Sealant (resistant to propane gas)
•
Manual shutoff valve
•
Ground joint union
•
Sediment trap
•
Tee joint
•
Pipe wrench
The installation location shall provide the following:
a. Adequate combustion and ventilation air, and
b. Adequate accessibility clearances for servicing.
Figure 4
Minimum Clearance From Combustible Construction
Rear
0.25 inches (with supplied spacers)
Sides
6 inches
Top
36 inches
Floor
6 inches
Summary of Contents for DVAG11
Page 16: ...16 Notes...