Page 55
Transport III Case Size: . . . . .17.93” W x 22.06” L x 10.43” H
(45.5 cm x 56 cm x 26.5 cm)
Shipping Case Size: . . . . . . .30.5” W x 25.75” L x 24.75” H
(77.47 cm x 65.40 cm x 62.86 cm)
525CF Weight (fully loaded): .57 lbs (25.8 kg)
Shipping Case Weight: . . . . .108 lbs (49 kg)
(fully loaded)
Power Source: . . . . . . . . . . . .AC Manual-Switching
115/220/230 VAC at 60/60/50 Hz
Power Rating: . . . . . . . . . . . .4.7A/4.9A at 50/60Hz, 115VAC
2.7A at 60Hz, 220VAC
2.3A/2.6A at 50/60Hz, 230VAC
Operating Pressure: . . . . . . . .45 - 55 PSI (3.10 - 3.79 bar)
High Volume Vacuum: . . . . . .5.8 SCFM @ 0” Hg (164.2 liters/min @ 0 cm Hg)
4.0 SCFM @ 4” Hg (113.3 liters/min @ 10.2 cm Hg)
Low Volume Vacuum: . . . . . .1.2 SCFM @ 1.5” Hg (33.9 liters/min @ 3.8 cm Hg)
Simultaneous Vacuum: . . . . .High @ 4” Hg = 3.2 SCFM (90.6 liters/min @ 10.2 cm Hg)
Low @ 1.5” Hg = 1.2 SCFM (33.9 liters/min @ 3.8 cm Hg)
Vacuum/Compressor Pump: .1.1 SCFM @ 50 PSI (31.0 liters/min @ 3.45 bar) Oilless Compressor
Water Reservoir Capacity: . . .33.9 fl. oz. (1.0 liters)
Air Storage Capacity: . . . . . . .25.4 fl. oz. (750 ml) nominal
Water Flow: . . . . . . . . . . . . . .5.07 fl. oz./min (0.15 liter/min)
Waste Container Capacity: . .0.48 gallon total/0.24 gal. per side (1.8 liters total/0.90 L per side)
(NOTE: Capacities reflect liquid volumes up to shutoff levels.)
Noise Level: . . . . . . . . . . . . . .70 dBA @ 3’4” (1 meter)
Case Duty Cycle: . . . . . . . . . .Continuous
Compressor Duty Cycle: . . . .Continuous when operating at 50/60 Hz
Electric Motor Duty Cycle: . . .17% (1 minute ON / 5 minutes OFF)
Environmental Conditions: . . .Operating Temperature: 0° to 40° C (32° to 104° F)
Transport/Storage Temperature: -20° to 65° C (-4° to 149° F)
Relative Humidity: 10 to 95% non-condensing
Altitude: 0 to 3048 meters (0 to 10,000 feet)
SPECIFICATIONS
This device has been tested and found to comply with the emissions requirements of
IEC 60601-1-2:2001-09. These requirements provide reasonable protection against
harmful electromagnetic interference in a typical medical installation. However, high
levels of radio-frequency (RF) emissions from electrical devices, such as cellular
phones, may disrupt the performance of this device. To mitigate disruptive
electromagnetic interference, position this device away from RF transmitters and
other sources of electromagnetic energy.
IMPORTANT
When running the
Transport III unit at 50Hz,
expect approximately 17%
less vacuum and pressure
volume due to slower
turning of the compressor.
NOTE
With regard to setting
the handpieces
pressure, 'kgcm2' and
'bar' are equivalent.
1013.3
hPa
697
hPa
10%
95%
0°C
(32°F)
40°C
(104°F)
OPERATING
TEMPERATURE
-20°C
(-4°F)
65°C
(149°F)
TRANSPORT &
STORAGE
TEMPERATURE
41EJ
MEDICAL -- GENERAL MEDICAL EQUIPMENT
AS TO ELECTRICAL SHOCK, FIRE AND MECHANICAL
HAZARDS ONLY, IN ACCORDANCE WITH:
UL 60601-1: First Edition
- Medical Electrical
Equipment, Part 1: General Requirements for Safety.
ANSI/AAMI ES60601-1:2005/(R)2012 and A1:2012,
C1:2009/(R)2012 and A2:2010/(R)2012
- Medical
electrical equipment—Part 1: General requirements
for basic safety and essential performance.
CAN/CSA C22.2 NO. 60601-1-08 (2013)
- Medical
Electrical Equipment - Part 1: General Requirements
for Basic Safety and Essential Performance (Adopted
IEC 60601-1:2005, third edition, 2005-12), Includes
Corrigendum 1:2011.