Your new Aseptico Express Air 2 Portable Dental System 

is the finest portable electric dental system available. The 

ADU-17A2 features two handpiece controls, a 3-way air/

water syringe, HVE and saliva ejector vacuum systems, a 

self contained water system, oilless air compressor, and 

vacuum pump. The dual voltage system comes in a case 

with wheels and a handle for maximum portability.

Congratulations!

This system is engineered to provide many years of reliable 

service. Please read the instructions provided in this 

manual to receive the best and longest service from your 

Aseptico equipment.

Separate manuals may be provided to cover the operation 

and maintenance of other accessories for your unit.

PACKAGE CONTENTS:

• Portable Case with Compressor and Vacuum Pump
• TA-90D 3-Way Air/Water Syringe
• HVE and Saliva Ejector Vacuum Hoses with Valves
• Water Supply Bottle
• AA-42 Air Foot Control (Complete Assembly with Fittings: 

PN 330699)
• Power Cord
• Operation & Maintenance Manual
• Highspeed or Lowspeed Pneumatic Handpieces 

(Purchased separately)
• AWS-1C Cavitron Connector
• Two Spare 6A Fuses for 120V Operation 

 

SAFETY PRECAUTIONS:

Aseptico accepts no liability for direct or consequential 

injury or damage resulting from improper use, arising in 

particular through the non-observance of the operating 

instructions, or improper preparation and maintenance.

WARNING: 

 

Sterilize before first and all uses. Clean, 

disinfect, and sterilize new or repaired instruments 

before first use. Only use sterilized handpieces and 

instruments during treatment. Non-sterile handpieces 

and instruments may cause bacterial or viral infections. 

Always sterilize instruments after operation.

CAUTION:

 

 Always examine unit components for damage 

before commencing treatment. Damaged components 

must not be used and must be replaced.

CAUTION:

 

 For device transport, always keeps the pull 

handle in hand during transport and ensure stable 

platform before releasing.

WARNING: 

 

Use for intended purposes only. Failure to 

observe the operating instructions may result in the 

patient or user suffering serious injury or the the 

product being damaged, possibly beyond repair. Before 

using this product, make sure that you have studied 

and understood the operating instructions.

WARNING: 

 

For use by qualified and trained personnel 

only.

WARNING: 

 

Do not install where there is a risk of an 

explosion. The Express Air is not intended for operation 

in the presence of flammable anesthetics or gases.

WARNING: 

 

Always operate a high-speed handpiece with 

water coolant. Operating a high-speed handpiece 

without water coolant can cause thermal injury to the 

patient and damage the handpiece.

WARNING: 

 

Only connect device to AC outlet with 

Protective Earth (Safety Ground) connection.

WARNING: 

 

The power supply cord is the mains appliance 

disconnect means.  Before use, position the 

equipment so it is readily accessible.

Expected Service Life:

The expected service life is seven years from the date of 

first use.

Summary of Contents for ADU-17A2 Express Air 2

Page 1: ...ADU 17A2 Express Air 2 Portable Dental System OPERATION and MAINTENANCE INSTRUCTION MANUAL...

Page 2: ...t if ignored CAUTION Damage to property or the environment may result if ignored NOTE Important additional information and hints Conforms To AAMI STD ES60601 1 AAMI IEC STD 62366 IEC STD 80601 2 60 IE...

Page 3: ...first and all uses Clean disinfect and sterilize new or repaired instruments before first use Only use sterilized handpieces and instruments during treatment Non sterile handpieces and instruments ma...

Page 4: ...he Voltage Selector Insert must be installed in the 120 position for 120V 60Hz operation or in the 240 position for 230V 50Hz operation WARNING ALWAYS DISCONNECT POWER TO THE SYSTEM BEFORE OPENING VOL...

Page 5: ...strument as shown in Figure 4 Attach the hose connector coming from the Vacuum Motor to this large white connection Connect the High Volume Vacuum HVE hose to the large gray connector located on the f...

Page 6: ...ses air Pressing both buttons simultaneously dispenses an air water mist 5 WATER SUPPLY BOTTLE The Express Air 2 incorporates a self contained pressurized water system This system consists of a 1 lite...

Page 7: ...d you have made yourself familiar with the system functions there are two operating modes to select from On Off Switch Operation Switch ON activates the vacuum and 3 way air water syringe Foot Pedal O...

Page 8: ...and between each patient use WATER LINES Disinfect the water lines weekly Prepare a 1 10 bleach solution 1 part household bleach to 9 parts water Remove water reservoir and discard residual water Rep...

Page 9: ...Check system s power connection Turn On Off switch ON for operation Check that voltage selector module is set for source voltage Check fuse If blown replace with 6A 125V medium time delay fuse for 12...

Page 10: ...Pressure 45 50 PSI 344 kPa Average Air Flow Pressure 35 PSI High Volume Vacuum 3 0 SCFM 4 Hg 84 9 liters min Low Volume Vacuum 1 4 SCFM 1 5 Hg 39 6 liters min Water Reservoir Capacity 33 9 fl oz 1 0...

Page 11: ...r its designated and authorized warranty service center This warranty shall not apply to products 1 that have been subjected to neglect abuse misuse improper installation inadequate maintenance or dam...

Page 12: ...12 P O Box 1548 Woodinville WA 98072 8333 216th Street SE Woodinville WA 98072 425 487 3157 800 426 5913 www aseptico com info aseptico com PRINTED IN THE U S A P N 420967 Rev G ECO 15498 04 2022...

Reviews: