Aseptico ADU-17A2 Express Air 2 Operation And Maintenance Instruction Manual Download Page 2

i.

INDICATIONS FOR USE:

The ADU-17A is a mobile self-contained dental 

system that is used for endodontic and general 

dentistry applications.

RX: FEDERAL LAW RESTRICTS THIS DEVICE 

TO SALE BY OR ON THE ORDER OF A DENTIST

P.O. Box 1548 • Woodinville, WA 98072

8333 216th Street S.E. • Woodinville, WA 98072

International (425) 487-3157 • Toll Free(800) 426-5913

www.aseptico.com • [email protected]

To prevent injury to people and damage to 

property, please heed relevant warnings and 

remarks. They are marked as follows:

•  WARNING:

 Serious injury or death may 

result if ignored.

•  CAUTION:

 Damage to property or the 

environment may result if ignored.

•  NOTE: 

Important additional information and 

hints.

Conforms To:

AAMI STD ES60601-1

AAMI IEC STD 62366

IEC STD 80601-2-60

IEC STD 60601-1-6

Certified To:

CSA STD C22.2 # 60601-1

TABLE OF CONTENTS:

Introduction .................................................................. 3

Package Contents ....................................................... 3

Safety Precautions ...................................................... 3

Setting Up the Unit ...................................................... 4

Figure 1 - ADU-17A2 System

 ................................ 4

Figure 2a the 2e - Changing Voltage

 .................... 5

Figure 3 - Installing Instrument Holder

 .................. 5

Figure 4 - Waste Tank Connections

 ...................... 6

Figure 5 - Saliva Ejector Connection

 .................... 6

Operation Functions .................................................... 6

Operation ..................................................................... 7

Figure 6 & 7- Handpiece Controls

 ...................7 & 8

Sterilization & Maintenance ......................................... 8

Figure 8 - TA-90D Syringe

 .................................... 8

Troubleshooting ........................................................... 9

Repacking Instructions .............................................. 10

Specifications

 ............................................................ 10

Symbol Definitions

 ......................................................11

Warranty .....................................................................11

Summary of Contents for ADU-17A2 Express Air 2

Page 1: ...ADU 17A2 Express Air 2 Portable Dental System OPERATION and MAINTENANCE INSTRUCTION MANUAL...

Page 2: ...t if ignored CAUTION Damage to property or the environment may result if ignored NOTE Important additional information and hints Conforms To AAMI STD ES60601 1 AAMI IEC STD 62366 IEC STD 80601 2 60 IE...

Page 3: ...first and all uses Clean disinfect and sterilize new or repaired instruments before first use Only use sterilized handpieces and instruments during treatment Non sterile handpieces and instruments ma...

Page 4: ...he Voltage Selector Insert must be installed in the 120 position for 120V 60Hz operation or in the 240 position for 230V 50Hz operation WARNING ALWAYS DISCONNECT POWER TO THE SYSTEM BEFORE OPENING VOL...

Page 5: ...strument as shown in Figure 4 Attach the hose connector coming from the Vacuum Motor to this large white connection Connect the High Volume Vacuum HVE hose to the large gray connector located on the f...

Page 6: ...ses air Pressing both buttons simultaneously dispenses an air water mist 5 WATER SUPPLY BOTTLE The Express Air 2 incorporates a self contained pressurized water system This system consists of a 1 lite...

Page 7: ...d you have made yourself familiar with the system functions there are two operating modes to select from On Off Switch Operation Switch ON activates the vacuum and 3 way air water syringe Foot Pedal O...

Page 8: ...and between each patient use WATER LINES Disinfect the water lines weekly Prepare a 1 10 bleach solution 1 part household bleach to 9 parts water Remove water reservoir and discard residual water Rep...

Page 9: ...Check system s power connection Turn On Off switch ON for operation Check that voltage selector module is set for source voltage Check fuse If blown replace with 6A 125V medium time delay fuse for 12...

Page 10: ...Pressure 45 50 PSI 344 kPa Average Air Flow Pressure 35 PSI High Volume Vacuum 3 0 SCFM 4 Hg 84 9 liters min Low Volume Vacuum 1 4 SCFM 1 5 Hg 39 6 liters min Water Reservoir Capacity 33 9 fl oz 1 0...

Page 11: ...r its designated and authorized warranty service center This warranty shall not apply to products 1 that have been subjected to neglect abuse misuse improper installation inadequate maintenance or dam...

Page 12: ...12 P O Box 1548 Woodinville WA 98072 8333 216th Street SE Woodinville WA 98072 425 487 3157 800 426 5913 www aseptico com info aseptico com PRINTED IN THE U S A P N 420967 Rev G ECO 15498 04 2022...

Reviews: