background image

Aseko Pool Technology

aseko.com

Ag

Cl

pH

ASIN Aqua

User’s Manual EN

Summary of Contents for ASIN Aqua

Page 1: ...Aseko Pool Technology aseko com Ag Cl pH ASIN Aqua User s Manual EN...

Page 2: ...ool s Parameters 13 Setting Pool Filtration Parameters 13 Setting Water Parameters 15 pH Settings 16 pH Calibrating 16 Choose the function of Your ASIN Aqua 18 1 Free chlorine probe CLF 18 2 Redox pro...

Page 3: ...be Weight 2 pc Injection Valve 2 pc Aseko POOL TESTER or PE Tube 1 4 Water Valve 2 pc ASIN Aqua What you receive in your box Sanostrips Sharp knife Screws and dowels pH probe Flowmeter Filter CLF chlo...

Page 4: ...ty Install your ASIN Aqua indoor away from dust and high humidity and make sure all electrical connections are secure Do not open your ASIN Aqua or exchange any of the internal parts This will damage...

Page 5: ...housing Redox CLF probe housing Peristaltic pump for pH agent Cable for Redox or CLF probe Peristaltic pump for desinfection agent Tube fitting Tube fitting Water INLET for measuring water Water INLET...

Page 6: ...e weather conditions cause damage ASIN Aqua functional temperature range is 5 40 C WARNING y y Ensure pool water is chemically clean and free from dirt before installing your ASIN Aqua y y Do not inst...

Page 7: ...EFORE measuring water connection you must TURN OFF the ASIN Aqua Water supply for the probes Water supply Water outlet from probes must be led into the normal pressure into skimmer drain or accumulati...

Page 8: ...ge within your pool water 1 Insert your CLF or Redox probe in the left side of your ASIN Aqua and attach the cable using the screw fit connector 2 Insert your pH probe in the right side of your ASIN A...

Page 9: ...the tubes cleanly 2 Connect the water input on the left and the water output on the right Make sure the water pressure is not more than 1 5 bar 3 The water output from your ASIN Aqua can be connected...

Page 10: ...side of the chlorine pump of your ASIN Aqua 5 Connect your clear plastic tube from the right side of your chlorine pump to your chlorine injection valve y y Thread G 1 4 6 Ensure your valves are not b...

Page 11: ...the ASIN Aqua is used in a different manner not specified by the manufacturer the apparatus may not provide the full protection it is designed for RECOMMENDED To frequent switching ON OFF more the 4x...

Page 12: ...NT function allows you to test both pumps 1 From the start screen select SETTINGS 2 Select DOSING TEST 3 Select START in the yellow box on the left of the screen This starts the chlorine pump on the l...

Page 13: ...n is significantly below recommended levels You can also use Manual dosing to test the connections of the clear plastic tubes to the pH and chlorine pumps 1 In menu select SETTINGS then MANUAL DOSE pH...

Page 14: ...the filtration period and not the frequency RECOMMENDATION Recommended filtration period is 24 hours Minimum filtration period is 6 hours After you set the ASIN Aqua Pool Filtration parameters you mu...

Page 15: ...N Aqua 1 From the home screen select settings then PARAMETERS and then POOL PARAMETERS to reach the following screen 2 POOL Using the check boxes select your type of pool y y INDOOR y y OUTDOOR y y EX...

Page 16: ...systems For chlorine sanitized pools You can use pH 7 0 pH Calibrating WARNING The probes do NOT require calibration under most circumstances ASEKO calibrates the ASIN Aqua pH probes at the factory If...

Page 17: ...ually If different adjust the reading on the ASIN Aqua by pressing the and buttons so that they match and press OK to save RECOMMENDATION for precision calibrating use the test buffer pH 7 00 If the m...

Page 18: ...reach the following screen 1 If You have free chlorine probe Your Asin Aqua is already installed connected to pool water and to chemical agents y y Set up the chlorine level to 0 0 mg l y y Set up the...

Page 19: ...iven on your ASIN Aqua with the reading taken manually If different adjust the reading on the ASIN Aqua by pressing the and buttons so that they match and press OK to save When your manual chlorine re...

Page 20: ...g of Superchlorination agent directly to pool Fine tune y y Manuallly check the chlorine level in the pool water y y If the pool s chlorine level is to low or high adjust the mV redox settings to fine...

Page 21: ...ation dosing volume on 10 ml m3 per day if you use the active oxygen sanitation agent y y Set up the pH value to 6 8 Fine tune y y Manually check the chlorine or active oxygen level in the pool water...

Page 22: ...r For extreme conditions is 25 ml m3 per hour Too rapid pH change It can be caused by heavy rain filling of large volume of water or extreme use if that happens ASIN Aqua stops dosing pH agent for 2 h...

Page 23: ...nnector And connector for external display Internet connection The device is connected through LAN cable to the router Data are send in 10 seconds intervals to IP 217 11 244 139 port 10004 must NOT be...

Page 24: ...d you can also change setup value of pH and chlorine You can also chose which parameters you want to see on the display Thermometer connection y y Install temp holder to the pipe system then insert th...

Page 25: ...be change is made in the following way y y Turn the pump counterclockwise and remove it y y Loosen both ends of the tube and remove the tube y y Cut the tie strips and release the tube y y Use a new t...

Page 26: ...Replace every 6 months PH and Chlorine Pumps Check inside the pumps for damage The clear plastic tubes wear out during operation Replace tubes every 12 months 12073 Item Maintenance Procedure Recomme...

Page 27: ...e and pH agent to avoid blockages and damage to the valves y y Check the rubber seals of your valves regularly to prevent leaking Water does not flow to the probes y y Check the clear plastic tubes co...

Page 28: ...Aseko Pool Technology aseko com Ag Cl pH ASIN Aqua User s Manual EN...

Reviews: