Confi guration
Date and Time
To ensure the correct function of timers, set the current date and time.
Pool Volume
To ensure the correct function of ASIN AQUA Oxygen, enter the correct volume
of your. Calculate your pool volume in m
3
:
Length (L) times width (W) times depth (D) is volume (V) - (L × W × D = V).
Enter the value using + and - buttons.
WARNING:
The pool volume has eff ect on the maximum safe dose, enter the
correct value.
Filtration Timer
Filtration can be set to NONSTOP operation for 24 hours or to one, maximum to
two time periods.
Variable Pump Control
ASIN AQUA Oxygen allows to control the SPECK or PENTAIR variable output
circulating pumps. The pump runs at speed 2 in fi ltering periods, besides the
preset fi ltering (when the standard pump is off ) it runs at speed 1 (or can stay
switched off according to your choice). In case of backwashing, the pump is
running at speed 3.
Individual speeds 1, 2, 3 are adjusted directly on the pump according to the
respective pump manual.
Automatic Filter Washing
Considering that the ASIN AQUA Oxygen technology is in particular based
on the high effi ciency of fi ltering and removing even the fi nest impurities, it
is necessary to
wash the fi lter on a regular basis.
The automatic washing
function ensures the fi lter washing on a regular basis in the preselected
intervals.
To enable this function, it is necessary to use the automatic 5-way
BESGO valve.
Its moving is enabled by the relay switching on. When the
relay switches on, the BESGO valve is enabled and moved to the required
position by the action of pressure water or air. See the BESGO manual.