10
EN
5.2. STORAGE LEVELS WITH POWER SOCKET STRIPS
LOAD CAPACITY (KG/
DRUM PLATFORM)
IO90.195.120.K3.WDC
max.
75 kg
max.
50 kg
max.
180 kg
Standard interior equipment
Only special
interior equipment:
Order No. 38520
Order No. 38521
Order No. 38522
Order No. 38523
Only interior
equipment with grids:
Order No. 38776 / 38772
Order No. 38777 / 38773
Order No. 38778 / 38774
Order No. 38779 / 38775
IO90.195.060.K9.WDC
IO90.195.060.L8.WDC
IO90.078.059.057.U9.S
max.
25 kg
max.
50 kg
max.
25 kg
Standard interior equipment
drawer
Second level drawer
CAUTION:
The position of the shelves / 2nd level drawer and socket strips cannot be changed.
5.3. TOTAL POWER RATING OF THE POWER SOCKET STRIPS
Standard: single-phase, 230 V
Version
EU
CH
UK
FR
fusing
16 A
10 A
13 A
16 A
max. total power
3,68 kW
2,3 kW
2,99 kW
3,68 kW
Optional: 3-phase, 400 V (accessories article 38038)
Note on model with a width of 600 mm IO90.195.060.K9.WDC, IO90.078.059.057.U9.S: Only 2 of the 3
connected phases are required by the cabinet electronics. The third phase remains unused.
Version
EU
CH
UK
FR
fusing
3 x 16 A
3 x 10 A
3 x 13 A
3 x 16 A
max. total power
11,04 kW
6,9 kW
8,97 kW
11,04 kW
ATTENTION:
The load on the system is to be distributed as evenly as possible over the power socket strips! The
individual power strip must not be loaded with more than the specifi ed power max. (see table)!
The necessary fuse protection is to be provided by the customer!
6. STORAGE
ATTENTION:
Never store obviously damaged lithium-ion batteries inside buildings.
Dispose of them without delay in disposal containers that are provided outside the building and approved
for transport.
6.1. NOTES ON STORAGE AND CHARGING
Storage
• It is recommended to store new and used lithium-ion batteries separately (each on a diff erent storage level)
in the safety storage cabinet.
Occupation of the storage levels (IO90.195.XXX.XX.WDC)
Grid shelves may be covered only up to 60% by battery chargers and batteries in order to ensure trouble-free
operation of the fi re suppression system and suffi cient air circulation.
Summary of Contents for IO90.078.059.057.U9.S