USER MANUAL

Safety storage cabinets for storage 
and charging of lithium ion batteries

10 YEARS WARRANTY

Upon conclusion of an asecos service and maintenance agreement

(PREMIUM 

tariff)

, you will get a warranty extension for up to 10 years for your ION-LINE safety 

storage cabinet.

EP.V.32907.04 | 09/2022

Summary of Contents for IO90.078.059.057.U9.S

Page 1: ...and charging of lithium ion batteries 10 YEARS WARRANTY Upon conclusion of an asecos service and maintenance agreement PREMIUM tariff you will get a warranty extension for up to 10 years for your ION...

Page 2: ...2 EN IO90 195 060 K9 WDC IO90 195 060 L8 WDC IO90 078 059 057 U9 S IO90 195 120 K3 WDC ION CHARGE 90 ION CHARGE PRO 90...

Page 3: ...rials guaranteeing the highest quality standards asecos safety storage cabinets have complete authorisation documents We archive the authori sation documents for every individual cabinet keeping them...

Page 4: ...K9 WDC IO90 078 059 057 U9 S 14 9 4 IO90 195 060 L8 WDC 14 9 5 Contact 14 10 TECHNICAL DATA 15 11 TECHNICAL DRAWING 15 12 IO90 195 120 K3 WDC 16 12 1 Installation of the extraction unit 16 12 2 Conne...

Page 5: ...ed technical personnel you can prevent the malfunctions damage and corrosion damage that result from inappropriate transport Observe the upper limits for stored quantities loading etc The following su...

Page 6: ...ur specially trained staff ATTENTION The doors must be locked prior to transport The extraction unit is inside the cabinet and is only mounted after the in plant transport to the place of use 2 1 TILT...

Page 7: ...8 059 057 U9 S 1 2 3 IO90 078 059 057 U9 S plinth with castors 1 2 3 2 4 Q MOVER Order no 30037 available from your authorised dealer a upright transport b upright transport through standard doors hea...

Page 8: ...COMMISSIONING Before putting into operation for the first time the user must carry out an examination of the safety storage cabinet for possible damage such as defective or loose sealing elements cor...

Page 9: ...EM Lockers can be closed manually and each has a cylinder lock with its own key pair An additional master key opens all 7 lockers Lockers and keys can be individually numbered using the key ring set a...

Page 10: ...9 S Only 2 of the 3 connected phases are required by the cabinet electronics The third phase remains unused Version EU CH UK FR fusing 3 x 16 A 3 x 10 A 3 x 13 A 3 x 16 A max total power 11 04 kW 6 9...

Page 11: ...entilation for the avoidance of heat accumulation in the interior must run continuously Repairs to the extraction unit are only to be carried out by specialists specifically trained for this Given dam...

Page 12: ...transport NOTE for 2 door tall cabinets Evacuation by at least 2 persons is recommended CAUTION The doors must be locked before transport Depending on the door heights it may be necessary to remove th...

Page 13: ...nly be opened by authorised personnel e g fire brigade Depending on the duration of the fire an ignitable vapour air mixture may have formed therefore remove all ignition sources within a 10 metre rad...

Page 14: ...Within the context of the annual check all safety related parts the smoke detector and the alarm signalling will be checked 9 4 IO90 195 060 L8 WDC A necessary service is automatically indicated by th...

Page 15: ...9 8 97 11 04 Information applies to special interior equipment see chapter 5 2 1 With this model only 2 of the 3 phases are used IO90 195 060 L8 WDC IO90 078 059 057 U9 S Type 90 90 External dimensio...

Page 16: ...austed directly into the room Connection to an exhaust duct is not necessary 12 2 CONNECTION TO THE POWER SUPPLY Connections on the headpiece IO90 195 120 K2 WDC IO90 195 120 K3 WDC LED Operating gree...

Page 17: ...ctrical components is necessary 12 3 SELF TEST Starts 5 seconds after connection to the mains supply 1 2 3 4 5 6b 12 4 ERROR DURING SELF TEST 1 2 5 3 5 sec 4 5 ATTENTION After pressing the reset butto...

Page 18: ...10 12 6 POTENTIAL FREE ALARM CONTACT NOTE The potential free alarm contact is used to connect a signal to a control centre control room Direct integration into a fire alarm control panel FACP is not...

Page 19: ...distance to combustible materials need not be maintained however a distance of at least 150 mm to the fire suppression cartridge should generally be maintained After triggering of the fire suppressio...

Page 20: ...d the safety cabinet must be subjected to a thorough inspection so that both fire protection and CE conformity are maintained For this purpose the cabinet must be handed over to the main factory of as...

Page 21: ...21 EN...

Page 22: ...ating alarm tone The triggering detector can be identified by parallel to the alarm tone flashing LED Battery replacement due flashing short beep every 45 seconds see 11 5 Operational readiness flashe...

Page 23: ...perature fluctua tions humidity and the number of test alarms alarms among other things In the case of lithium this is up to 5 years The smoke detector announces a necessary battery change approx 30 d...

Page 24: ...rsonnel Initiation of necessary measures If the internal temper ature falls below 50 C the system returns to normal operation and the optical and acoustic signals are switched off Alarm 1 Temperature...

Page 25: ...re control room The potential free switching contact must always be connected by the customer not a service AC DC AC DC Connector Internal alarm contact Connection instructions Use only the supplied m...

Page 26: ...one The triggering detector can be identified by parallel to the alarm tone flashing LED Battery replacement due flashing short beep every 45 seconds see 13 5 Operational readiness flashes every 45 se...

Page 27: ...perature fluctua tions humidity and the number of test alarms alarms among other things In the case of lithium this is up to 5 years The smoke detector announces a necessary battery change approx 30 d...

Page 28: ...da Barcelona 34 935 745911 34 935 745912 info asecos es asecos bv Veiligheid en milieubescherming Tuinderij 15 NL 2451 GG Leimuiden 31 172 506476 31 172 506541 info asecos nl asecos Safety and Environ...