5.10.3 Open Door Alarm
The instrument can notify an
Open door alarm
activated by
the digital input with the function programmed as
i.Fi
=
5
or
6
.
When the digital input is activated, the instrument shows on
the display the label
oP
alternated to the variable set at pa-
rameter
i.dS
then, after the delay programmed at parameter
A.oA
, the instrument signals the alarm via the activation of the
configured alarm output (buzzer/ouput), lighting up the
LED
while continues displaying the label
oP
.
If
i.Fi
=
5
at open door alarm intervention the fans are reacti-
vated.
5.11 Function of Keys
,
and
Three of the instrument keys, in addition to their normal func-
tions, can be configured to operate other commands.
The key function can be defined by parameter
t.UF
, the
key function through parameter
t.Fa
and the key func-
tion through parameter
t.Fb
. All parameters can be config-
ured to perform the following functions:
oF
The key carries out no function;
1
Pressing the key for at least 1 s it is possible to enable/
disable the auxiliary output if configured as
o.Fo
=
3
;
2
Pressing the key for at least 5 s it is possible to enable/
disable a defrost cycle;
3
Pressing the key for at least 1 s it is possible to switch
the instrument from the ON status to Stand-by status and
vice versa;
4
Pressing the key for at least 1 s it is possible access the
SP1
fast Set Point set up;
5
Pressing the key for at least 1 s it is possible access the
SP2
fast Set Point set up.
6 ACCESSORIES
The instrument is equipped with a TTL port with a 5 poles con-
nector that allows to connect some accessories.
6.1 Parameters Configuration by A01
Through the TTL port the instrument allows the transfer of the
functioning parameters to/from the device
A01
.
This device it is mainly usable for serial programming those
instruments that need the same parameters configuration or
to keep a copy of the parameters setting of an instrument and
allow its fast duplication.
The same device allows to connect a PC via USB with which,
through the appropriate configuration software for “
AT Univer-
salConf tools
”, the operating parameters can be configured.
To use the
A01
device it is necessary that the device or instru-
ment are being correctly supplied.
AC supply
Supply adapter
12 VDC
Power
supply
Ente
r
PW
S
12
V
A B C
TTL
+
-
US
B
to PC
USB
Ente
r
PW
S
12
V
A B C
TTL
+
-
US
B
to PC
USB
For additional info, please look at the A01 instruction manual.