6  ACCESSORIES

The instrument is equipped with a TTL communication port 
with a 5-pole connector that allows the connection of some ac-
cessories described below.

6.1 

Parameters Configuration by A01

Through the TTL port and the 

A01

 device equipped with 

a 5-pole connector it is possible to transfer the operating 
parameters to and from the instrument.

This device it is mainly usable for serial programming those 
instruments that need the same parameters configuration or 
to keep a copy of the parameters setting of an instrument and 
allow its fast duplication.
The same device allows to connect a PC via USB with which, 
through the appropriate configuration software for “

AT Univer-

salConf tools

”, the operating parameters can be configured.

To use the 

A01

 device it is necessary that the device or instru-

ment are being correctly supplied.

AC supply

Supply adapter

12 VDC

Power 
supply

Ente

r

PW
S

12 
V

A B C 

TTL

+

-

US
B

to PC

USB

Ente

r

PW
S

12 
V

A B C 

TTL

+

-

US
B

to PC

USB

For additional info, please look at the A01 instruction manual.

6.2 

RS 485 Serial Interface by ARS1

Through the ARS1 device (TTL/RS485 interface) and the ap-
propriate TTL cable, it is possible to connect the instrument to 
a serial communication network (RS485 type) to which other 
instruments (controllers or PLC) are connected, all depending 
typically on a Personal Computer used as plant supervisor.

ARS1

B-

A+

Supply

CATTL I

Cable

RS485

D+

D-

Using a Personal Computer it is possible to acquire all the 
functionning data and program all the instrument configura-
tion parameters.
The software protocol adopted for the instrument is a 

MOD-

BUS-RTU

 type, widely used in several PLC and supervision 

programs available on the market (Y and Z series protocol 
manual is available on request).

HOST

(PC/PLC)

RS485

Interface

shield

ARS1

Y39H no. 1

TTL

ARS1

Y39H no. 2

TTL

Rt

120

ARS1

Y39H no. n

TTL

If the instrument is used in a MODBUS network, program, 
with parameter 

tAd

, the station Address.

Note: 

The baud-rate is fixed at 9600 baud.

ARS1 converter is directly supplied by the instrument.
For additional info, please consult the ARS1 instruction manual.

Summary of Contents for Y39H

Page 1: ...oling application with ON OFF control and humidity control humidification and deumidification with ON OFF control the instrument integrates an asymmetrical oscillator timer whitch can be used for spec...

Page 2: ...lashing 12 LED Stand By When the instrument is in Stand by mode is the only lit LED 13 LED Tm Time When flashes points out that the twin timer which operates on the Auxiliay output is enabled 2 Progra...

Page 3: ...ly entering the password is protected if the SET LED is steady ON the parameter is programmable without password not protected To change the parameter visibility press the key and keep ing it pressed...

Page 4: ...insert the instrument fixing it with the provided special brackets In order to obtain the declared front protection degree IP65 use the screw type bracket optional Avoid placing the instrument in env...

Page 5: ...obe Out2 Out1 Out3 TRH03 5 Functions 5 1 ON STAND BY Function Once powered the instrument can assume 2 different conditions ON The controller uses the control functions STAND BY The controller uses no...

Page 6: ...uration The instrument outputs can be configured by the relative pa rameters o o1 o o2 and o o3 The outputs can be configured for the following functions ot To manage the temperature control device In...

Page 7: ...ith neu tral zone r HC nr When r HC nr the output configured as ot operates with a cooling action like r HC C while the output configured as HE can be used to operate with a heating action The r d dif...

Page 8: ...the actuator motor or water injec tion solenoid valve 5 7 Compressor Protection Function and Delay at Power ON The compressor protection functions performed by the in strument are studied to avoid fre...

Page 9: ...AL A Lt A Ht A dt A dt time off off off ON ON Hit Lot Temp Pt or assume the values SP A Ht and SP A Lt if the alarms are relative A yt 2 AL A Lt SPt A Ht Temp Pt A dt A dt time off off off ON ON Hit L...

Page 10: ...uts are disabled at digital input intervention 5 8 4 Open Door Alarm The instrument can notify an Open door alarm activated by the digital input with the function programmed as i Fi 5 When the digital...

Page 11: ...PC USB Enter PWS 12 V A B C TTL USB to PC USB For additional info please look at the A01 instruction manual 6 2 RS 485 Serial Interface by ARS1 Through the ARS1 device TTL RS485 interface and the ap p...

Page 12: ...th Humidity and Tempearture measurements alterna ted every 10 s tt Tempearture and countdown t of measurements alternated every 10 s 3U Humidity Tempearture and countdown t of mea surements alternated...

Page 13: ...h 0 0 30 0 RH 1 0 43 A th Humidity alarm delay A Hh and A Lh oF 0 01 9 59 min s 99 5 min s x 10 oF 44 A PA Temperature and Hunidity Alarms delay at power ON oF 0 01 9 59 h min 99 5 h min x 10 2 00 45...

Page 14: ...ithout any fees or charge for Ascon Tecnologic except in the event of alterna tive agreements 10 Technical Data 10 1 Electrical Data Power supply 12 VAC DC 12 24 VAC DC 100 240 VAC 10 AC Frequency 50...

Page 15: ...EN61000 4 5 supply 2 kV com mode 1 kV diff mode EN61000 4 6 3 V 11 How to order MODEL Y39H Instrument with mechanical keyboard a POWER SUPPLY H 100 240 VAC G 12 24 VAC VDC F 12 VAC VDC b OUT1 OUTPUT...

Page 16: ...Ascon Tecnologic Y39H Line Operating Instructions Pag 16...

Reviews: