Ascon Tecnologic Srl - X33H

 

– OPERATING INSTRUCTIONS – MX33HENG00 - PAGE 15

 

the time “btEd” 
3= 

Switches 

off 

regulator 

(stand-by) 

without any signalling 
4= 

Switches 

off 

regulator 

(stand-by) 

signalling 

“End” 

and 

activating the buzzer for 
the time “btEd” 
5= 

Continues 

to 

regulate 

on 

step3 

(without any signalling) 
6= 

Continues 

to 

regulate 

on 

step3 

signalling 

“End” 

and 

activating the buzzer for 
the  time  “btEd”  at  the 
end of step 3 
7=  Resumes  regulating 
from 

step 

(and 

continues the cycle) 
8=  Resumes  regulating 
from 

step 

(and 

continues the cycle) 

103 

btEd

  Time of activation of the 

buzzer for signalling the 
end of the cycle 

OFF ÷ 99.59 

min.sec. 

OFF   

 

6 - PROBLEMS, MAINTENANCE AND GUARANTEE

 

 
6.1 - SIGNALS 
Error signals

Error

 

Motive

 

Action

 

E1 

-E1

 

The  Pr1  sensor  may  be 
interrupted or short circuited, or 
it measures a value outside the 
allowed range  

E2 

-E2

 

The  Pr2  sensor  may  be 
interrupted or short circuited, or 
it measures a value outside the 
allowed range 

E3 

-E3

 

The  Pr3  sensor  may  be 
interrupted or short circuited, or 
it measures a value outside the 
allowed range 

E4 

-E4

 

The  Pr4  sensor  may  be 
interrupted or short circuited, or 
it measures a value outside the 
allowed range 

Check  the  correct 
connection  of  the 
sensor 

to 

the 

appliance  and  then 
check  the  correct 
operation 

of 

the 

sensor  

EEPr

 

Internal memory error 

Check, 

and 

if 

necessary, 
reprogram 

the 

operating 
parameters. 

Other signals:

 

Signal

 

Motive

 

od

 

Delay upon switching on in progress 

HI 1

 

Maximum Pr1 temperature alarm 

LO 1

 

Minimum Pr1 temperature alarm  

HI 3

 

Maximum Pr3 temperature alarm 

LO 3

 

Minimum Pr3 temperature alarm 

HI 4

 

Maximum Pr4 humidity alarm 

LO 4

 

Minimum Pr4 humidity alarm 

od

 

Delay upon switching on in progress 

dEF

 

Defrosting in progress with “dLo”=Lb 

PdEF

 

Post-defrosting in progress with “dLo”=Lb 

AL

 

Digital input in progress alarm 

AdoP

 

Door open 

1. / 2. / 3.

 

Cycle in execution 

1.P / 2.P / 3.P

 

Cycle in execution in pause phase  

End

 

Cycle terminated 

6.2 - CLEANING

 

It is recommended that the appliance only be cleaned using a soft 
cloth  dampened  with  water  or  a  non-abrasive  detergent  that  does 
not contain solvents. 

 
6.3 - GUARANTEE AND REPAIRS

 

The  appliance  is  guaranteed  against  defects  in  construction  or 
material defects encountered within 12 months of delivery.   
The guarantee is limited to the repair or replacement of the product.  
Any opening of the housing, tampering with the appliance, or non-
compliant use and installation of the product automatically voids the 
guarantee.  In  the  event  of  a  defective  product,  either  within  the 
guarantee  period  or  outside  the  guarantee  period,  contact  the 
TECNOLOGIC sales office to obtain authorization for shipping.  
The  defective  product,  hence,  accompanied  by  the  indications  of 
the  defect  encountered,  should  be  sent  postage  paid  to  the 
TECNOLOGIC facilities, unless otherwise agreed. 
 

7 - TECHNICAL SPECIFICATIONS

 

 
7.1 - ELECTRICAL SPECIFICATIONS

 

Power supply:  100...240 V AC +/- 10% 
AC frequency: 50/60 Hz 
Absorption: 4 VA approximately 
Input/s: 3 inputs for NTC (103AT-2, 10 K 

 @ 25 °C) or PTC (KTY 

81-121, 990 

 @ 25° C) temperature sensors; 1 0/4..20 mA input; 1 

digital  input  for  voltage-free  contacts  +  2  digital  inputs  for  voltage-
free  contacts  as  an  alternative  to  the  Pr2  and  Pr3  temperature 
inputs. 
Output/s: up to 4 relay outputs.  Out1 SPST (16A-AC1, 6A-AC3 250 
V AC, 1 HP 250 V AC, 1/2HP 125 V AC); Out2  SPDT (8A-AC1, 3A-
AC3 250 V AC,1/2 HP 250 V AC, 1/3HP 125 V AC); Out3 and Out4  
SPST-NO (5A-AC1, 2A-AC3 250 V AC, 1/8 HP 250 V AC, 1/10HP 
125 V AC). 12 A Max. for model with extractable terminal block  
Electrical lifetime of relay outputs: 100,000 op. 
Action: type 1.B compliant with EN 60730-1 
Overvoltage category:  II 
Device class: Class II 
Insulation:  Reinforced  between  parts  under  low  voltage  (type  H 
power  supply  and  relay  outputs)  and  frontal;  reinforced  between 
parts  under  low  voltage  (type  H  power  supply  and  relay  outputs) 
and parts under very low voltage (inputs); reinforced between power 
supply and relay outputs. 

 
7.2 - MECHANICAL SPECIFICATIONS

 

Container: Self-extinguishing plastic UL 94 V0 
Category of resistance to heat and fire:  D 
Dimensions: 78 x 35 mm, depth 75.5 mm 
Weight: 160 g approximately 
Installation:  Built-in  flush  with  panel  (max.  thickness  12  mm)  in  a 
cavity measuring 71 x 29 mm 
Connections:  2.5  mm

2

  screw  clamps  or  removable  connector  with 

2.5 mm

2

 screw clamps  

Degree of frontal protection: IP 65 (NEMA 3S) with seal 
Degree of pollution: 2 
Ambient working temperature:  0 T 50 °C 
Ambient working humidity: < 95 RH% without condensation 
Temperature of transport and storage: -25 T 60 °C 

 
7.3 - MECHANICAL DIMENSIONS, DRILLING AND FIXING [mm]

 

64

11,5

1

9

2

8

5,5

78

3

5

X33H

.

.

.

.

F1

F2

 

Summary of Contents for X33H

Page 1: ...PARAMETER PROGRAMMING 2 5 CONFIGURATION OF THE PARAMETERS WITH A01 2 6 KEYPAD LOCK 3 WARNINGS FOR INSTALLATION AND USE 3 1 PERMITTED USE 3 2 MECHANICAL INSTALLATION 3 3 ELECTRICAL CONNECTIONS 3 4 ELE...

Page 2: ...n the value set will be memorized and the display will then move on to read SP h humidity Set point and the value set for it To modify this value use the UP and DOWN keys The SP h Set point can be set...

Page 3: ...ted with a 5 pole connector The A01 device can be used for the serial programming of appliances that must have the same configuration of the parameters or for keeping a copy of the programming of one...

Page 4: ...upply the appliance can be in one of 2 different states ON means that the controller actuates the control functions STAND BY means that the controller does not actuate any function and the display is...

Page 5: ...sabled The buF par allows the buzzer to be enabled YES or disabled no 4 4 TEMPERATURE REGULATOR All the parameters regarding the regulation of the temperature are contained in the rEG group The regula...

Page 6: ...he appliance is switched on for the time set in the od par During the phase of delay upon switching on the display will show the indication od alternating with the normal programmed messages The delay...

Page 7: ...hether the recycling fans must be switched on FdF On or whether they should switch off during defrosting FdF OFF In this last case it is possible to delay the re starting of the fans even after the en...

Page 8: ...he alarm conditions of the appliance are Errors in Sensors E1 E1 E2 E2 E3 E3 E4 E4 Temperature alarms HI 1 LO 1 HI 2 LO 2 HI 3 LO 3 HI 4 LO 4 External alarm AL Door open alarm AdoP 4 13 1 TEMPERATURE...

Page 9: ...upon the closure of the input and after the did time the alarm is activated and the appliance alternately shows on the upper display AL and the variable established in the diSU par 2 Signalling of an...

Page 10: ...cle the cycle is interrupted and the appliance returns to the normal regulation state STOP 7 START PAUSE STOP mode When the command is given by key the cycle is started START If the key is pressed for...

Page 11: ...the event that it is envisaged that the operator cannot be present at the end of this phase and thus cannot extract the product it is possible to program a third maintenance phase For this third phase...

Page 12: ...temp Pr3 Measurement of OFF Pr1 Pr2 Pr3 Pr4 SPt SPh Pr4 Pr3 sensor auxiliary temp Pr4 Measurement of Pr4 sensor humidity SPt Active temperature Set Point SPh Active humidity Set Point rEG group param...

Page 13: ...shold for high Pr3 temperature OFF 58 0 302 0 C F OFF 62 LAL3 Alarm threshold for low Pr3 temperature OFF 58 0 302 0 C F OFF 63 dAL3 Differential of Pr3 temperature alarms 0 0 30 0 C F 2 0 64 ALd3 Del...

Page 14: ...t AL ALL On End HEAt 86 Out3 Configuration of operation of OUT3 output see Out1 OFF CooL HEAt rh drh dEF FAnr FAnE drhE LIGH AuS ALt rH 87 Out4 Configuration of operation of OUT4 output see Out1 OFF C...

Page 15: ...encountered within 12 months of delivery The guarantee is limited to the repair or replacement of the product Any opening of the housing tampering with the appliance or non compliant use and installa...

Page 16: ...measurement sampling 130 ms Display 4 digit 1 Red and 1 Amber yellow h 7 mm Class and structure of the software Class A Conformity Directives 2004 108 CE EN55022 class B EN61000 4 2 8KV air 4KV cont E...