Ascon tecnologic e33B Operating Instructions Manual Download Page 6

Ascon Tecnologic - e33B - OPERATING INSTRUCTIONS - PAG. 6

If 

iEt

 = 

oF

 the selection of Eco/Normal modes via the digital 

input is disabled.
If 

itt

 = 

oF

 the time-out switching from Eco to Normal mode 

is disabled.

Temp.

SPE

SP

rd

rEd

iEt

 (1)

iEt

time

Normal

Normal

eco

iTt

 (2)

Pr1

Switching to Economic mode is indicated by the label 

Eco

.  

In addition, the selection of the 

Eco

 mode is always com-

bined with the function of turning OFF the output configured 
as 

L1

 (showcase light).

5.2.2 

Turbo/Normal/Eco mode selection

Turbo

 mode can be used manually when, after a refrigerator 

load phase, a products temperature decrease is required.
It can instead be used automatically to allow the recovery of 
the products temperature at the end of an Economic cycle.

Turbo

 mode can be selected manually:

 

Pressing 

/  

turbo

 and maintaining it pressed for 5 s;

 

From digital input if parameter 

i.Fi

 = 

8

;

Turbo

 mode can be selected automatically:

 

Leaving 

Eco

 mode (only if 

rHC

 = 

C3

)

 

Every time the instrument is switched ON (only if 

rHC

 = 

C3 

and 

Pr1

 > 

SPE

 + 

rEd

)

The instrument quits 

Turbo

 mode automatically at the end of 

rtC

 time or manually using the programmed command (key or 

digital input), the instrument always returns to 

Normal

 mode.

Setting 

rHC

 = 

C3 

the operating cycle is:

 

At power ON, the instrument starts in the mode it was in 
when it was switched OFF (

Normal

 or 

Eco

) unless the tem-

perature at power ON is > 

SPE

 + 

rEd

.  In this case (see 

the drawing) a 

Turbo

 cycle is automatically started.

 

After time 

rtC

 the instrument automatically switches to 

Normal

 mode.

 

If the door is opened frequently, the instrument remains in 

Normal

 mode.  If however the door is not opened for time set 

at 

iEt

 parameter, it automatically switches to 

Eco

 mode.

 

The instrument remains in 

Eco

 mode until the door is 

opened again or, if set, until the time-out 

itt

.

 

On leaving 

Eco

 mode the instrument therefore runs a 

Turbo

 cycle to allow product temperature to be restored, 

after which it reverts to 

Normal

 mode and so on.

Temp.

SPE

SP

SPH

rHd

rEd

itt

 (2)

rtC

rtC

time

Normal

Turbo

Turbo

iEt

 (1)

rd

Pr1

eco

Notes: 1. 

The time 

iEt

 is reset every time the door is ope-

ned, in the case shown the door is always closed.

2. 

The 

itt

 time is stopedas soon as the door is 

opened, the instrument immediately switches 
to 

Turbo

 mode.  In the case shown, the door is 

always closed.

5.3 

Measure and display configuration

With parameter 

iuP

 it is possible to select the tempera-

ture engineering unit and the desired measure resolution 
(

C0

 = °C/1°; 

C1 

= °C/0.1°; 

F0

 = °F/1°; 

F1

 = °F/0.1°).

The instrument allows the measure calibration, which can 
be used to recalibrate the instrument according to applica-
tion needs, the calibration is made by using parameters 

iC1

 

(input Pr1), 

iC2

 (Pr2 input) and 

iC3

 (Pr3 input).

Parameters 

iP2

/

iP3

 allow to select the controller usage of 

Pr2

/

Pr3

 probe measure as:

EP

 

Evaporator probe

: used to manage the defrost and 

the evaporator fans (see relative functions).

Au

 

Auxiliary probe

: can be used as a display-only probe, 

but it is also possible to associate temperature alarms 
(possible uses: product probe, anti-freeze probe, etc.);

DG

  Digital Input only for 

Pr3

 input.

If probe input is not used, set 

iP2

 or 

ip3

 = 

oF

.

Two inputs cannot be set to perform the same function.   
If two inputs are set to do the same function, this is done 
only by the 

Pr2

 input.

Using 

iFt

 parameter is possible to set a software filter to 

decrease the input sensibility to rapid temperature changes, 
increasing the sampling time, to stabilize the reading of the 
measurement inputs.
In addition to this filter there are other two similar filters used 
only for the 

Pr1

 probe measure visualization, these regard the 

increasing (

tdu

 parameter) and the decreasing (

tdd

) of 

Pr1

 

measurement to avoid to display fast temperature variations.
The filter blocks the maximum decrement displayed at 0.1° 
every 

tdd

 seconds and the maximum increase displayed 

every 

tdu

 seconds. These filters are reset at power OFF.

Through the 

idS

 parameter is possible to set the variable 

normally displayed:

P1

 Pr1 

probe measurement;

P2

 Pr2 

probe measurement;

P3

 Pr3 

probe measurement;

SP

 

Active Set Point;

Ec

 

Pr1

 probe measure if the instrument is in 

Normal

 

mode, the label 

Eco

 if the instrument is in 

Eco

 mode;

oF

 

If the numerical display must be switched OFF.

When one of the measures is displayed (

idS

 = 

P1

/

P2/P3

/

Ec

the 

iCU

 parameter allows to set an offset that is applied only 

to the displayed variable (all controls are made according to 
the correct temperature value, changed only by the calibra-
tion parameters).
Regardless of what is set at 

idS

 parameter, all the measure-

ment variables can be shown as descibed at paragraph: “

2.7 

- Variables display

”.

It is also noted that the 

Pr1

 probe display can also be changed 

by “

Defrost display lock

” function via the 

ddL

 parameter  

(see the 

Defrost function

).

Summary of Contents for e33B

Page 1: ...ration through stopping the compressor electric heating or hot gas cycle inversion The controller is equipped with special defrost optimization functions and with other functions that can be used to o...

Page 2: ...Stand by mode this is the only lighted LED In programming mode while the parameter code is displayed the dot indicates the parameter protection level not protected lit up protected flashing and hidde...

Page 3: ...ial test keeping it pressed for 5 s In this way it is possible to access all the parameters verify and modify the parameter tPP 2 4 Customized mode parameter programming parameters programming level T...

Page 4: ...d rule must adopt all the necessary protective measures The instrument MUST NOT BE USED in dangerous environ ments flammable or explosive without adequate protections The instrument used with NTC 103A...

Page 5: ...1 A Out 3 2 1 A 60730 EN UL 5 FUNCTIONS 5 1 ON Stand by function Once powered the instrument can assume 2 different conditions ON Means that the controller uses the control functions STAND BY Means t...

Page 6: ...always closed 5 3 Measure and display configuration With parameter iuP it is possible to select the tempera ture engineering unit and the desired measure resolution C0 C 1 C1 C 0 1 F0 F 1 F1 F 0 1 The...

Page 7: ...that is NO in normal operation then closed during the alarm AL To control an alarm that cannot be silenced through a contact that is NO in normal operation then closed during the alarm An To control a...

Page 8: ...s automatic switching between the three Normal Eco Turbo modes described at the paragraph Operating modes The time protections described in the next paragraph PP1 PP2 PP3 always work on the ot configu...

Page 9: ...a chines in which is required the maximum evaporator efficiency at each compressor cycle To enable automatic defrost at intervals after setting the ddC parameter as desired between rt ct or cS with th...

Page 10: ...related to the EP probe under which defrosts are possible Therefore in the indicated modes if the temperature meas ured by the EP probe is higher than the one set at parameter dtS and also dtE defros...

Page 11: ...emperature alarms Hi and Lo External alarm AL Door open oP The alarm functions acts on LED on the internal buzzer if present and configured by the obu parameter and on the desired output if configured...

Page 12: ...The instrument can signal an alarm external to the instrument using the digital input setting iFi 4 or 5 The instrument signals the alarm turning ON the alarm LED and display ing AL label alternated...

Page 13: ...f some instruments which need to have the same parameters con figuration or to keep a copy of the parameters settings of an instrument and allow its rapid retransmission The same device allows to conn...

Page 14: ...ck 3 Open Door with Fan and Output Lock 4 External Alarm 5 External alarm with control output disabling 6 Normal Eco select 7 On Stand by select 8 Start a Turbo cycle 2 15 iti Digital Input Delay oF D...

Page 15: ...n disabled 1 59 s 1 99 min 5 42 FtF Fan time deactivation with ot output compressor OFF oF Function disabled 1 59 s 1 99 min oF 43 FFL High temperature fan deactivation 99 9 999 C F 10 0 44 FLF Low te...

Page 16: ...otu Time relative to auxiliary output oF Function disabled 1 59 s 1 99 min oF 67 tUF Key Function oF No function 1 Eco Mode direct selection turn OFF the showcase light if configured 2 Switch ON Swit...

Page 17: ...faults found without any fees or charge for Ascon Tecnologic except in the event of alternative agreements 10 TECHNICAL DATA 10 1 Electrical characteristics Power supply 230 VAC 115 VAC 12 VAC VDC 10...

Page 18: ...C 103AT11 11 INSTRUMENT ORDERING CODE MODEL e33B Instrument with mechanical keyboard a POWER SUPPLY D 230 VAC C 115 VAC F 12 VAC VDC b OUTPUT 1 OUT 1 H Out1 Relay SPST NO 16A AC1 for resistive loads R...

Page 19: ...Ascon Tecnologic e33B OPERATING INSTRUCTIONS PAG 19...

Reviews: