TD 92372GB
2007-06-18/ Ver. E
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway
28
5
Select system user name and password, see
6
Set the mode to Master, see
7
8
Select tones, see
9
Enter gatekeeper IP address or ID, see
10
Set the master IP address to 127.0.0.1, see
Enter IP Address to the Master
11
Perform a reset to restart the IPBS/IPBL in master mode, see
If problem to access the master from a certain PC after the reset;
• Open a command window in windows by selecting Start > Run and enter
"cmd" in the
Open:
text field.
• Enter the following commands
arp -d
(Delete the
arp
cache)
nbtstat -R
(Empty the
nbtstat
cache)
• Restart the WEB browser.
12
Select supplementary services, see
Configure Supplementary Services
13
Assign PARI, see
14
Enter SARI, see
Note:
In some SW versions SARI is not available and a licence is needed, see
15
Enter IMS IP address, see
16
Configure air synchronization, see
17
Enter the Time Server address, see
18
Reset in order to make the configuration changes take effect, see
6.4
Configure the Standby Master
It is recommended to have a standby master in the IP-DECT system. This section describes
how to configure a standby master. Each configuration step is briefly described in the step
list below, for more detailed information see the corresponding subsection in
1
Determine the address and access the GUI, see
2
Change the default password, see
3
Set a static IP address and set DHCP to off, see
4
Enter system user name and password, this should be the same user name and
password as in the Master. See
Change System Name and Password
5
Set the mode to standby master, see
6
Enter gatekeeper address, see
7
Enter master IP address, see