7.12 Reset
Some configuration changes requires a reset in order to take effect. A reset reboots the
software. There are two ways to perform a reset:
• Idle reset - waits until there are no active calls in the IPBS/IPBL.
• Immediate reset - clears all calls and resets the IPBS/IPBL.
7.12.1 Idle Reset
1
Select Reset > Idle Reset.
2
Click "OK".
3
The IPBS/IPBL will reset when there are no active calls.
7.12.2 Immediate Reset
1
Select Reset > Reset.
2
Click "OK".
3
The IPBS/IPBL will terminate all active calls and reset.
7.12.3 TFTP Mode
Note:
When the IPBS/IPBL is in TFTP mode it can only be reached using the gwload utility.
This mode should not be used during normal operation.
7.13 Reset Using the Reset Button
It is possible to do a hardware reset of the IPBS and IPBL by pressing the reset button. The
button is accessed through a hole in the back of the IPBS (
on page 2) and on the
front of the IPBL (
Note:
Use a pointed object in an non conducting material to perform a reset.
Short press < 1 sec
Restart
Medium press ~3 sec
Restart in TFTP mode. In TFTP mode the IPBS and IPBL
can be accessed only through the gwload application.
This mode is intended for support and development
departments.
Long press ~ 10 sec
Factory reset - all configuration parameters will be set to
default values.
8
Commissioning
This section describes the visual inspection and tests that must be executed after
completing the installation and initialization of the IP-DECT system. The purpose of the
visual inspection and tests is to verify that all installation activities have resulted in a
correctly functioning system. If it appears that a part is malfunctioning while the system is