The  pilot  burner  nozzle 

(C)

  is  situated  underneath  the  pilot  burner.  Unscrew  the  pilot  gas  line  from  the 

floor and pull gently downwards. Change the ignition nozzle at the end of the ignition gas line and screw 
on again. 

 

Once the conversion is completed, the appliance must be subjected to a complete test just as if it were an 
initial commissioning! 

 

10 

Umstellanleitung Gas - Bratplatte 

C

B

A

Zündbrenner mit

Zündbrennerkappe

Hauptdüse

Kleinbranddüse

Gashahn PEL 21S

Schlauchleitung

Flachdichtung

Brennerdeckel

Überwurfmutter M16x1,5 SW 19

Doppelkegelring 10 mm

Verschlußschraube SW 14
Steckschlüssel SW 5,5

Thermoelement

Zündgasleitung

Burner cover 

Thermocouple 

Screw plug A/F 14 

Socket spanner A/F 5.5 

Cap nut, M16x1.5 A/F 19 

Olive, 10 mm 

Hose piping 

Gas valve PEL 21 S 

Pilot gas line 

Low flame nozzle 

Main nozzle 

Pilot burner with pilot 
burner cap 

Flat gasket 

Conversion instructions, gas frying plate 

Summary of Contents for AGB 23 Series

Page 1: ...EN EN English Language Version Operating Instructions ASCOLINE 700 AGB 23x AGB 43x Gas frying plate Quality and Competence in Stainless Steel ...

Page 2: ...Rectification 6 7 1 Fault rectification 6 7 2 Customer service 6 8 Spare Parts 7 8 1 List 7 9 Conversion Instructions 7 10 Overview of Nozzle Sets for Gas Frying Plate 8 11 Overview of the Categories acc to Country 9 12 Declaration of Conformity 10 Annexes Technical Data Sheet Cleaning and Care Instructions Dear customer Read carefully through these operating instructions before putting the applia...

Page 3: ...ve 3 2 Safety instructions for operating cleaning and repair Overheated fats and oils can be self igniting The preparation of food using fats and oils should not be left unsupervised Never try to extinguish fat or oil using water Put Gastronorm 1 1 or 2 1 lid on the appliance and switch off Put all knobs to Off and then close the gas supply valve within the customer s extent of supply The frying p...

Page 4: ...r similar which are made of flammable materials Otherwise there is danger of fire See connection diagram with equipment description for minimum distance Local fire protection regulations must be strictly observed It is of importance that the equipment be set up absolutely horizontal use spirit level for alignment so that the doors can be opened and closed without any problem and that they seal tig...

Page 5: ...frame When attaching the appliance to an installation wall cantilever or wall mounted frame ACC 881 the appliance connections from below or from the rear must be used 4 2 3 Wall table top appliances connected through the rear wall On the right hand side in the rear corner is a bracket that is screwed on with downwards penetration that covers the access to the installation channel to the rear Remov...

Page 6: ...annot be operated without the dirt tray Please note that the capacity of every dirt tray is finite 5 4 Cleaning Please observe the hygiene regulations in your company The instructions in this document are not a substitute for such regulations observe the tips for handling stainless steel appliances in commercial kitchens Attention Appliances may not be cleaned using water under pressure spraying w...

Page 7: ...flame can be ignited but it does not last Control knob not in the correct position or not pressed long enough or hard enough Hold down control knob in ignition position at the end stop for about 10 seconds Irregular flame pattern Burner is dirty Remove burner and clean it Clear out the holes with a pin or needle X Smell of gas Pipes connecting components leaky Knob in 0 position close main tap A r...

Page 8: ...alers The use of nozzles other than those authorised for the gas supply correction pressure leads to destruction of the appliance and to health hazards for the personnel CO emission The gas adjustments carried out in the factory are given on the gas type plate Subsequent conversions to other gas types or supply pressures must be entered permanently and legibly on the gas type plate of the applianc...

Page 9: ...ce the conversion is completed the appliance must be subjected to a complete test just as if it were an initial commissioning 10 Umstellanleitung Gas Bratplatte C B A Zündbrenner mit Zündbrennerkappe Hauptdüse Kleinbranddüse Gashahn PEL 21S Schlauchleitung Flachdichtung Brennerdeckel Überwurfmutter M16x1 5 SW 19 Doppelkegelring 10 mm Verschlußschraube SW 14 Steckschlüssel SW 5 5 Thermoelement Zünd...

Page 10: ...5 1 AGB 230 AGB 238 260 260 B50 P67 0 86 2 0 47 2 KZ 5 2 AGB 430 AGB 438 261 261 P50 0 90 1 0 50 1 KZ 5 1 AGB 230 AGB 238 262 262 P50 0 90 2 0 50 2 KZ 5 2 AGB 430 AGB 438 11 Overview of the Categories acc to Country Usable categories for different countries according to DIN EN 437 with connection pressure in mbar Possible conversion for gas frying plates Natural Gas Liquefied Gas Category 2H 2LL 2...

Page 11: ... type Version Ident No Free standing appliances AGB 230 Gas frying plate open cabinet 6575 000 AGB 430 Gas frying plate open cabinet 6576 000 Wall and table top appliances AGB 238 Gas frying plate 6675 000 AGB 438 Gas frying plate 6676 000 satisfy the provisions of the EC Gas Appliances Directive EU2009 142 EC including modifications valid at the time of the declaration The following harmonised st...