Operating Instructions for Ascoline 700, AES 060, AES 080
ascobloc
Gastro-Gerätebau GmbH
D - 01156 Dresden, Grüner Weg 29
Germany
Tel. +49 351 4533-0
Fax +49 351 4537-339
E-mail:
AESxxx.doc Status: 21.06.2019
Subject to change without notice!
8
7.1 Fault rectification
Fault
Cause
Remedy
Green indicator light is on,
but there is no heat
Heating, power level switch or
temperature limiter defective,
one phase has failed
Replace defective component
No heat produced at the
electric boiler
Power connection to equipment
interrupted
Fuse in customer supply is open
Green indicator light is on,
but there is no heat
-> heating element faulty
Restore supply
Restore supply
Replace heating element
Contact breaker trips
repeatedly
Wrong contact breaker or short-
circuit
Replace
Green indicator light does
not light after power is
switched on
Mains connection or contact breaker
defective
Indicator light is faulty
Replace contact breaker
Appliance does not heat
Not enough water in the double
jacket, TLP has tripped
Top up water (see 4.4) then press in
the knob again on the TLP (see
Figure 2; No. 15)
Lid does not remain in the
open, upright position or
does not close completely
Spring force is not correct
Hinge faulty
Adjust spring force (see 6.1)
Replace spring
Drain cock is leaking or
difficult to move or
jammed
No lubrication
Wrong plug has been inserted after
the cleaning
Lubricate with suitable grease
(see 5.3)
Fit valve housing/plug that have the
same number
A repair may only be performed by trained, qualified specialists. Please give us the equipment number
and the type designation that are on the equipment name plate. The plate is located on the front cover A
of the equipment (see connection diagram).
7.2 Customer service
ascobloc Customer Service: Tel.
+49 351 4533–384
Fax
+49 351 4533–379