4.4  Filling the double jacket 

The appliance must be completely disconnected from the mains.  
Remove the front panelling. Loosen the clamp at the Y-piece (A) and pull off the hose (C) from the Y-
piece  (A)  (the  connecting  hose  is  not  yet  attached  when  it  is  the  first  filling).  Lead  the  piece  of  hose 
remaining on the boiler to the outside of the equipment. 

 

 

 

 

 

 

 

 
 

Attention!

 

When filling the jacket, the pressure may not 

exceed 0.5 bar.  
 
Exceeding this pressure causes irreparable damage to 
the boiler! 
For this reason, attach the filling hose as loosely as 
possible to the water tap! 

 

Connect a water hose to the filling tap (B). 
Open the filling tap and let the water run in till the water runs 
out at the hose (C). Close the filling tap.  
Open  the  safety  valve  (D)  by  turning  the  knurled  nut 
anticlockwise. The safety valve (D) is open when a clicking 
noise is heard during the turning of the nut. This opening of 
the  valve  ventilates  and  vents  the  water  bath  and  avoids 
overfilling.  When  no  more  water  runs  out  of  the  hose  (C), 
close the safety valve (D) by turning the knurled nut in the 
opposite direction till it comes to the end stop. 
Connect the hose (C) to the Y-piece (A) again. 

 

All panelling and cladding parts must be attached again 
once the filling work has been completed! 

 
 
 

Draining the double jacket

 

The jacket only has to be emptied when the boiler is put into 
store or for other reasons when a temperature of below 0°C 
is to be reckoned with. 
For the draining of the jacket, just as for the filling, the filling 
tap (B) is opened and the hose (C) pulled off the Y-piece (A). 

 
 
 
 
 

4.5  Functional test 

  Fill the pan with the minimum water quantity (approx. 10 litres). 

  Put the appliance into operation. The green indicator light for operational readiness must light up. 

  Set the desired temperature. The yellow indicator light for the control must light up. 

  The  boiling  pan  must  go into the control mode  once  the  set  temperature is  reached;  the  yellow  light 

goes out. 

5  Proper Usage 

5.1  Operational start-up

 

Remove the protective film before bringing into operation. 
Clean the equipment with dilute soap solution. 
Check that the lid hinge functions properly before bringing into operation for the first time. Should the lid 
no longer remain standing in the uppermost position or not close automatically in the lower position, the 
hinge should be adjusted as described in Section 6.1. 

Summary of Contents for AES 060

Page 1: ...Operating Instructions ASCOLINE 700 AES 060 AES 080 Electric Fast Boiling Pans Quality and Competence in Stainless Steel 1 ...

Page 2: ...ures to be taken for longer stoppages 7 7 Faults and their Rectification 7 7 1 Fault rectification 8 7 2 Customer service 8 8 List of Spare Parts 9 8 1 List 9 8 2 Illustrations 11 9 Declaration of Conformity 15 Annexes Technical Data Sheet Connection Diagram Cleaning and Care Instructions Dear customer Read carefully through these operating instructions before putting the equipment into operation ...

Page 3: ...quipment description for minimum distance Local fire protection regulations must be kept to absolutely Before operating the equipment for the first time the double jacket of the appliance must be filled with water see 4 4 to avoid damaging the appliance When filling the boiler the water pressure may not exceed 0 5 bar If the safety valve of the steamer blows off steam steam outlet in the foot area...

Page 4: ...is to have shims fitted underneath to compensate for unevenness if required 4 1 1 Free standing set up If the equipment is to be set up on its own suitable means are to be used to protect it against tilting and shifting 4 1 2 Setting them up in groups or blocks When setting up in groups or blocks the equipment must be joined together by connecting elements provided for this purpose This is for the...

Page 5: ...ids overfilling When no more water runs out of the hose C close the safety valve D by turning the knurled nut in the opposite direction till it comes to the end stop Connect the hose C to the Y piece A again All panelling and cladding parts must be attached again once the filling work has been completed Draining the double jacket The jacket only has to be emptied when the boiler is put into store ...

Page 6: ...r such regulations Observe the tips for the treatment of stainless steel appliances in commercial kitchens Attention Appliances may not be cleaned using water under pressure spraying with water hose or steam jet or high pressure cleaners The appliance is to be shut off if the surroundings are to be cleaned using such means The appliance must be shut off and adequately cooled down before cleaning A...

Page 7: ...eamer is to be checked for mobility and function Lid hinge If the lid does not stay in the upright position the lid hinge must be readjusted Figure 4 Lid hinge To do this unscrew the protecting cap S2 and turn the screw inside to the right using an all key Lubricating lid hinge e g POLYLUB WH2 from the Klüber Company lubricant for food processing technology If the lid is difficult to move unscrew ...

Page 8: ...t after power is switched on Mains connection or contact breaker defective Indicator light is faulty Replace contact breaker Appliance does not heat Not enough water in the double jacket TLP has tripped Top up water see 4 4 then press in the knob again on the TLP see Figure 2 No 15 Lid does not remain in the open upright position or does not close completely Spring force is not correct Hinge fault...

Page 9: ...2 1 Leaf spring for knob 12 3657 X 13 Scale ring two stroke switch 08 2956 14 Scale ring three stroke switch 08 2939 15 Temperature limiter 09 3689 X 16 Power contactor 09 4196 X 17 Micro fuse 09 2017 X 18 Lid hinge 04 5209 X 18 1 Special grease for valves 50 g 15 1659 19 Mixing valve 08 1177 X 20 Ball type knob dia 40 x M10 09 2245 X 21 Unit safety drain valve 1 type 6726 60 incl fitting fat 20 g...

Page 10: ... 01156 Dresden Grüner Weg 29 Germany Tel 49 351 4533 0 Fax 49 351 4537 339 E mail service ascobloc de AESxxx doc Status 21 06 2019 Subject to change without notice 10 31 Hose connector 12 1088 X 32 Steam condenser assembly AES 060 04 10704 X 32 1 Steam condenser assembly AES 080 04 11109 X ...

Page 11: ...ny Tel 49 351 4533 0 Fax 49 351 4537 339 E mail service ascobloc de AESxxx doc Status 21 06 2019 Subject to change without notice 11 8 2 Illustrations Figure 1 Control panel AES 080 shown Figure 2 Control box AES 080 shown Control panel front view without knobs for hot and cold water Rear view of control panel 16 17 15 24 ...

Page 12: ...56 Dresden Grüner Weg 29 Germany Tel 49 351 4533 0 Fax 49 351 4537 339 E mail service ascobloc de AESxxx doc Status 21 06 2019 Subject to change without notice 12 Figure 3 View of what is behind the front panel AES 080 shown Figure 4 Lid hinge AES 080 shown Figure 5 Safety valve AES 080 shown ...

Page 13: ...ascobloc Gastro Gerätebau GmbH D 01156 Dresden Grüner Weg 29 Germany Tel 49 351 4533 0 Fax 49 351 4537 339 E mail service ascobloc de AESxxx doc Status 21 06 2019 Subject to change without notice 13 Figure 6 Steam condenser assembly AES 080 shown 32 and 32 1 ...

Page 14: ...eg 29 Germany Tel 49 351 4533 0 Fax 49 351 4537 339 E mail service ascobloc de AESxxx doc Status 21 06 2019 Subject to change without notice 14 Figure 7 Safety discharge valve 6726 60 04 10255 08 8511 List of Spare Parts Item 21 Figure 8 Safety discharge valve 6724 63 04 10712 08 8153 List of Spare Parts Item 22 ...

Page 15: ...the time of the declaration The following harmonised standards were applied EN 60335 2 47 2012 12 Household and similar electrical appliances Safety Part 2 47 Particular requirements for commercial electric boiling pans EN 60335 1 2012 10 Household and similar electrical appliances Safety Part 1 General requirements EN 55014 1 2012 05 Electromagnetic compatibility Requirements for household applia...

Reviews: