Put off ornaments, such as ring, necklace, watch and bracelet, before you operate under live 
working. When metal articles connect the power to the ground,   short circuit happens and 
components may be damaged. 

 

 

Pull out the AC power socket and close the direct-current power before operating on the 
machine box or working beside the power source. 

 

 

When the power is on, do not touch the power. 

 

 

Correctly connect the device and the power socket. 

 

 

Only professionals are allowed to operate and maintain the device. 

 

 

Read the installation guide carefully before the system is powered on.

 

Notes: 

 

1.

 

Check potential dangers, such as the humid floor, ungrounded extensible power line and tatty 
power line.  

2.

 

Install the emergent on-off at the working room for turning off the power when trouble happens.  

3.

 

Turn off the power on-off of the switch and plug off the power line before installing or uninstalling 
the machine box or working beside the power.  

4.

 

 Do not work alone if potential dangers exist.  

5.

 

 Cut off the power before checkout.  

6.

 

 If trouble happens, take the following measures: 

 

Cut off the system's power. 

 

Alarm. 

 

Take proper measures to help persons who are hit by the disaster. Artificial respiration is 
needed if necessary. 

 

Seek for medical help, or judge the loss and seek for available help.  

 

Electrostatic discharge may damage devices and circuits. Improper treatment may cause the 
switch to malfunction completely or discontinuously. 

 

Move or locate the devices according to the measures of electrostatic discharge prevention, 
ensuring the machine box connects the ground. Another measure is to wear the static-proof 
hand ring. If there is no hand ring, use the metal clip with the metal cable to clip the 
unpainted metal part of the machine box. In this case, the static is discharged to the ground 
through the metal cable of the clip. You can also discharge the static to the ground through 
your body.

 

 

This part describes the requirements for the installation locations.

 

Summary of Contents for AS3424S

Page 1: ...ACT AS3424S 24 x 10GE Layer 3 Switch Installation Guide Revision B...

Page 2: ...duction in any manner whatsoever without the express written permission of Ascent Communication Technology is strictly forbidden This document is produced to assist professional and properly trained p...

Page 3: ...2 Installation Preparation 7 2 1 Caution of Usage 7 2 2 Safety Advice 7 2 3 Requirements for Common Locations 8 2 4 Installation Tools and Device 10 3 Installing the ASCENT AS3424S Switch 11 3 1 Insta...

Page 4: ...ont template of the ASCENT AS3424S switch Table 1 2 Parts at the front template of the ASCENT AS3424S switch No Abbrev Name Description 1 Power LED indicator Power indicator refer to indicator descrip...

Page 5: ...802 3x Flow control IEEE 802 3z asymmetric flow control IEEE 802 3ad Link aggregation IP Routing Protocol Standard RFC 1058 RIP RFC 1723 RIP v2 RFC 1583 OSPF v2 Network Management Standard RFC 1157 SN...

Page 6: ...AS3424S Hardware Installation Guide Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 6 of 22 Output current 5A MAX Full Power Consumption 75W...

Page 7: ...to national laws and regulations or send these products to our company for collective processing Keep dustless and clean during or after the installation Put the cover at the safe place Put tools at t...

Page 8: ...ch and plug off the power line before installing or uninstalling the machine box or working beside the power 4 Do not work alone if potential dangers exist 5 Cut off the power before checkout 6 If tro...

Page 9: ...following content assists you to make a proper cabinet configuration Each device on the cabinet gives off heat when it runs Therefore the sealed cabinet must have the heat discharge outlet and the coo...

Page 10: ...devices to install the ASCENT AS3424S switch are not provided by the ASCENT AS3424S switch You yourself need to prepare them The following are the tools and devices needed for the typical installation...

Page 11: ...nals are allowed to install or replace the devices The installation of the machine box has two modes Installing the machine box on the desk Installing the machine box on the cabinet The ASCENT AS3424S...

Page 12: ...See Figure 3 2 Figure 3 4 Installing the switch on the cabinet The switch of ASCENT AS3424S has a console port The rate of the console port is a value ranging from 1200bps to 115200bps It has a standa...

Page 13: ...th the value from 1 to 8 Figure 3 4 Connecting the console port of ASCENT AS3424S and computer Warning The switch shown in figure 3 4 does not represent the material ASCENT AS3424S Table 3 1 Pins of t...

Page 14: ...8 Figure 3 5 RJ 45 connector on the console port Because the 10 100 1000Base T ports of ASCENT AS3424S support the MDI MDIX self identification of the cable ASCENT AS3424S can adopt five types of dir...

Page 15: ...e SFP optical module to the SFP port and then you can connect other Ethernet terminal devices through the optical cable Figure 3 7 Connecting the 10GE SFP port and other Ethernet terminals Warning The...

Page 16: ...vides with 1 USB2 0 interface Before electrically starting up the switch perform the following checkups after the switch is installed If the switch is installed on the cabinet check whether the instal...

Page 17: ...he switch required tools and operation methods Warning When the power cable still connects the power source do not touch it When you open the cover the switch you may use the following tools Crossed s...

Page 18: ...the machine box is hard to install The section mainly describes how to put the cover and close the machine box Do as follows 5 Put them well according to their locations and joint them together along...

Page 19: ...ion 2 3 Requirements for Common Locations If the switch cannot be started and the PWR indicator is off check the power Do the following checkups to help remove the fault If the port of the switch cann...

Page 20: ...ly linked If the indicator is off the port is not linked If the indicator flickers there is data transmission 2 The 40GE port breaks out into 4 10GE ports The 4 port indicators are on in turn The inte...

Page 21: ...AS3424S Hardware Installation Guide Solutions Provider for FTTx RFoG and HFC www ascentcomtec com Page 21 of 22 Figure 5 3 QSFP port indicator...

Page 22: ...nit 1907 600 Luban Road 2710 Thomes Ave 200023 Shanghai CHINA Cheyenne WY 82001 USA Phone 86 21 60232616 Phone 1 203 816 5188 EUROPE VIETNAM Pfarrer Bensheimer Strasse 7a 15 F TTC Building Duy Tan Str...

Reviews: