background image

 

 

2

asberprofessional.com

 

 

 

 

 

 

 

 

 

 

 

 

 

asberprofessional.com

 

INSTALLATION 

2.1 Transport, handling, unpacking, location. 
2.2 Manufacturer

’s identification label description. 

2.3 Installation and assembly. 
2.4 Gas Connections 

 

2.1 

Transport, handling, unpacking, location 

Upon receiving your new ASBER Equipment, check the package and the machine for any damages that 
may have occurred during transportation. Visually inspect the exterior of the package. If damaged, open 
and inspect the contents with the carrier. Any  damage should be noted and  reported on the delivering 
carrier

’s receipt. 

 
In  the  event  that  the  exterior  is  not  damaged,  yet  upon  opening,  there  is  concealed  damage  to  the 
equipment notify the carrier immediately. Notification should be made verbally as well as in written form. 
Request an inspection by the shipping company of the damaged equipment. Retain all crating material 
until inspection has been made. Finally, contact the dealer through which you purchased the unit. 
 

2.2 

Manufacturer’s identification label description

 

Information  on  this  plate includes  the model,  serial  number,  BTU  /  hour input  of the  burners  operating 
gas pressure in inches WC, and whether the appliance is orifices for natural or propane gas. 
 
When communicating with factory about a unit or requesting for special parts or information, 
Rating plate data is essential for proper identification. 
 

ASBER  COOKING  APPLIANCES  MUST  BE  CONNECTED  ONLY  TO  THE  TYPE  OF  GAS 
IDENTIFIED ON THE RATING PLATE 
 

 

 

Model 

Gas Type 

Serial Number 

 

Summary of Contents for AEF-2525 S

Page 1: ...5 NG Manual instructions Installation and Operation Manueltalimatlar Kurulum ve al t rma Manual de instrucciones Uso y mantenimiento Manuel d instructions Installation et fonctionnement Bedienungshinw...

Page 2: ...ion and assembly 3 2 3 1 UNCRATING 3 2 3 2 INSTALLATION OF LEGS 3 2 4 Gas Connections 5 2 4 1 MANUAL SHUT OFF VALVE 5 2 4 2 PRESSURE REGULATOR 5 2 4 3 THIS APPLIANCE IS EQUIPPED FOR NATURAL GAS GAS 5...

Page 3: ...t is design engineered for commercial use only 1 2 IMPORTANT SAFETY INFORMATION WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Rea...

Page 4: ...aled damage to the equipment notify the carrier immediately Notification should be made verbally as well as in written form Request an inspection by the shipping company of the damaged equipment Retai...

Page 5: ...n making delivery File claim for damages immediately Regardless of extent of damages Concealed loss or damage If damage is noticed after unpacking notify transportation company immediately and file Co...

Page 6: ...twist caster shaft in the biggest hole Inside there is a welded nut to hold caster shaft STEP 4 Repeat step 3 for each caster and verify the base of caster abuts the base frame Important you will hav...

Page 7: ...oming service line for safe and efficient operation the gas pressure regulator supplied by ASBER must be installed at the gas inlet of each piece of equipment The regulators supplied along with ASBER...

Page 8: ...ocal installation codes Before Installation please read instructions completely and carefully Do not remove permanently affixed labels warnings or plates from the product Please observe all local and...

Page 9: ...p dial depressed for about 30 seconds or until pilot stays lit before releasing 6 If the pilot does not stay lit repeat step 4 and 5 7 Turn gas tap dial on the combination gas valve to on position 8 T...

Page 10: ...ight the pilot and turn on the burners 5 When the solution starts to boil turn off the thermostat and let the vessel soak to soften the deposit and or carbon spots Approximately 1 hour 6 Drain off sol...

Page 11: ...thermopile c Turn and set gas tap dial to ON position d Set thermostat to desired temperature e Replace f Replace Fryer does not heat up fast a Insufficient gas b Line clogged c Overloading the fryer...

Page 12: ...y Normal parts wear and maintenance is also not covered by this warranty This warranty is in lieu of any other agreement expressed or implied and constitutes the only warranty of ASBER with respect to...

Page 13: ...sberprofessional com ASBER Circuito Exportaci n N 201 Parque Industrial Tres Naciones San Lu s Potos S L P M xico 13105 NW 47th Ave Miami Fl 33054 www asberprofessional com MULTI SOLUTION MANUFACTURER...

Reviews: