ASAHI YUKIZAI Dymatrix AVHPRS User Manual Download Page 7

取扱説明書

 

User’s  Manual 

AVHPRS                                                                                                                                                                                                                                                                                       

 

V

⑤Oリング

 

 

O-ring 

※1

12

⑦操作ポート接続

  Pilot port

無記入

 n/a

Rc 1/8"

FNPT 1/8"

   T

※4

下ネジ穴 Thread at bottom

9.53 x 6.35

12 x 10

12.70 x 9.53

Flare Type

Tube

1

⑥固定方法

 Mounting

10 x 8

Basa plate

台  座

0

N

6 x 4

本体材質

 Body Materials

PTFE

6.35 x 4.35

□50

□60

③規格

 Tubing Standard

Millimeter

Inch

インチ

ミ リ 

M

I

06

   F

※3

Super 300 Type Pillar Fitting

Super Type Pillar Fitting

Flowell 60 series

Flowell 20 series

2

6

S

3

10

T

AVHPR

50

□50

①タイプ

 Type

②チューブ径

  

Connection

 

tubing

 

size

60

□60

F

K

EPDM

バイフロン

®

 F 

※2

Viflon

®

 F

カルレッツ

®

 6190

Karlez

®

 6190

FKM

E

T

④接続方法

 Connection

④  型式選定   

How to select types

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

※1 接続方法“F”の場合は、規格“I(インチ)”のみ選択できます。
※2 Tubeの外径、内径サイズはP.9をご参照下さい。
※3 Oリングは接液しません。
※4 バイフロン®F は耐酸用三元系弗素ラバーです。

 

 

 

 

Ordering code example

AVHPR50-T063V0

AVHPR50-T063V0-N

※1 Oリングは接液しません。
※2 バイフロン

®

F は耐酸用三元系弗素ラバーです。

※3 接続方法“F”の場合は、規格 I“(インチ)”のみ選択できます。
※4  Tubeの外径、内径サイズは接続方法・Tubeサイズをご参照 下さい。
     

※1 O-rings are not wetted.
※2 ”Viflon” is the Terpolymerization Fluorocarbon  Elastomers.
※3 In the case of the connection is “F”, only “I(Inch)” can be selected 
      for the “Tubing Standard“. 
※4 Please refer to “Connection・ tube”size  for diameter of “Tube“.
    

Summary of Contents for Dymatrix AVHPRS

Page 1: ...Serial No DTS168 01 General cautions Part names Specifications How to select types Dimension How to operate Technical data How to installation How to piping Check items Causes of defects and how to co...

Page 2: ...User s Manual AVHPRS 1 General cautions 1 2 AV V 029 EJ N2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 1 2...

Page 3: ...User s Manual AVHPRS 2 1 1 AV V 029 EJ N2 2 3 4 5 6 1 2 3 4...

Page 4: ...alve unable to seal 4 Please contact us when use for the fluid containing the crystalline substance It would make the valve unable to seal 5 Use the products within the range of working pressure shown...

Page 5: ...nding on the working condition If cavitations are observed review the fluid pressure and piping design 3 Do not use the valve in negative pressure It can be damaged 4 Handle the products carefully to...

Page 6: ...inlet pressure is from minimum working pressure to 0 3MPa and there is no back pressure change Proof Pressure 0 5 72 5psi Working Pressure range 0 03 0 3 Pilot pressure 4 35 43 5psi Max setting Press...

Page 7: ...Pillar Fitting Flowell 60 series Flowell 20 series 2 6 S 3 10 T AVHPR 50 50 Type Connection tubing size 60 60 F K EPDM F 2 Viflon F 6190 Karlez 6190 FKM E T Connection How to select types Ordering co...

Page 8: ...56 inch mm S 89 55 inch mm 3 88 inch F 106 58 inch mm T 110 inch 105 mm 102 inch 138 mm 134 inch mm S 113 71 inch mm 3 110 inch F 122 71 inch mm T 102 inch 113 73 mm 110 73 inch 138 72 mm 134 72 inch...

Page 9: ...diameter tolerance Connection tubing size 06 10 12 Super Type Pillar fitting 6 35x3 95 9 53x6 33 12 7x9 5 Super 300 Type Pillar fitting 12 70x9 53 Flowell 60 series Flare Type Tube Unit mm Connection...

Page 10: ...ctronic Pneumatic regulator 7 Please do not use the regulator without the exhaust function The valve may not operate precisely 8 Please leave the pilot air pressure off in case the valve is not used f...

Page 11: ...rence Flow Range Flow rate Downstream pressure Pilot pressure Flow rate Pilot pressure Downstream pressure The data shown here is the experimental values and the reference values Upstream pressure Dow...

Page 12: ...60 Upstream pressure Downstream pressure Upstream pressure Flow rate Flow rate Downstream pressure Pilot pressure Flow rate Pilot pressure Downstream pressure Orifice Reference Flow Range The data sho...

Page 13: ...mensions see Dimension Flow direction Always flow medium in a specified direction Please check the arrow sticker on the side of the body before mounting 0 4 0 6N m Be careful about the screw length Fa...

Page 14: ...User s Manual AVHPRS 13 How to piping Flowell 20 series 1 2 Flowell 60 series Super Type Pillar fitting Super 300 Type Pillar fitting Flare Type...

Page 15: ...he inner surface of the tube Insert the tube provided with the ring into the main body by hand Turn nut up to the required clearance by spanner after tightening by hand firmly To check the tightness o...

Page 16: ...n Plastic air couplings Sealing tape 1 0 2 0 4 N m 2 3 1 Always use plastic couplings and tighten them to a torque between 0 2 and 0 4 N Overtightening them with a spanner or the like may break the pr...

Page 17: ...mends you to check them at least once a year When finding any problem or trouble call us Check points Check items Actuator Appearance flaw crack distortion discoloration Leakage of the pilot air Do no...

Page 18: ...he downstream side of the orifice Check the piping The upstream pressure is low Check the operating conditions Flaw in the diaphragm or body Replace the valve Foreign matter is caught in the valve Lea...

Page 19: ...ose of product improvement 2020 12 v01 110 0005 3 24 6 21 TEL 03 5826 8832 FAX 03 3834 7592 For inquiries contact Head Office Overseas Department Tel 81 3 5826 8831 Fax 81 3 3834 7592 21st Floor Ueno...

Reviews: