9
①
General Set-up Precautions
(1) This airless spray equipment uses compressed air for the fluid displacement pump.
Use a compressor with a capacity of 1.5kW (2PS) or larger.
(2) Supply dry compressed air.
Wet compressed air, if supplied, may cause pump failure, such as valve shifting
error, due to freezing or rusting. Watch water accumulation, etc. in the
compressor tank.
(3) Pressure drop occurs when a compressor is installed in a place far removed from the pump. The
maximum compressed air pressure supplied to the pump is 0.5 Mpa.
Determine the capacity of compressor taking the compressor-to-pump distance into account.
(4) Securely ground the grounding wire.
Connect a ring crimp terminal (that comes with the equipment) to the pump grounding
terminal , the other clip to a Class D grounding object.
Improper grounding may cause electric shock, fire or explosion.
(5) When you noticed any failure symptom, take corrective actions in accordance with the “Tear Down
Inspection and Parts Replacement” (pages 13 and 14) and “Troubleshooting” (pages 15 and 16).
If your problems still exist after you did all this, don’t try to do anything further but immediately
contact our agency near you or Asahi Sunac directly, giving us details about the problems. Please
rest assured; we’ll take care of them.
②
Unpacking and Connections
(See pages 18 through 24 for part names.)
Being 100% inspected at the factory before shipment, the airless pump is ready for operation once
connections are made with a hose and gun. Upon unpacking, however, please check the contents
thoroughly for any damage that may have occurred in transit and for missing parts. If you find
anything wrong, please get in touch with our agency near you or us directly at Asahi Sunac.
(1) Upon unpacking you’ll find that the equipment, high-pressure hose, and spray gun are not
assembled yet. You’ll have to put them together in the manner as described below:
(2) Connect a ring crimp terminal (that comes with the equipment) to the pump grounding
terminal , the other clip to a Class D grounding object.
Improper grounding may cause electrical shock, fire or explosion.
(3) Connect the accumulator hose to the joint at the outlet of cylinder-shaped material filter.
And connect the fluid hose to the joint further down.
Ensure that the fluid hose is hooked up securely. A loosely connected hose
may provide injection and splash hazards, possibly causing personal injury or
accident.
(4) Mount the spray gun at the end of high-pressure fluid hose. At this point, do not put the nozzle on,
yet.
When you mount the spray gun, lock trigger. If you fail to lock the trigger, it
may be pulled accidentally and personal injury may result.
(5) Connect the air hose to the nipple at the air regulator inlet.
With this you have made all the connections that have to be made.
3
Setting Up for Operation
CAUTION
WARNING
WARNING
WARNING
WARNING