English
Operation manual
25
3. In the tester menu select the test mode for alternators (Fig.7, n.4) and then, select the
alternator type (Fig.9). The tester will switch over to the test mode.
3.1* Upon activation of the test mode, the control lamp indicator must light up.
* This does not apply to the alternators of SIG and P/D types.
3.2 If this is the alternator with COM terminal, wait for the tester to readout the data. As soon
as the values appear in ID, Version LIN, and Type boxes, proceed to testing.
4. Start the vehicle engine and turn the load off. Wait for it to run steadily at idle speed. The
stabilizing voltage shall set at 13.8V, the allowable deviation is ±0,2V.
4.1 The stabilizing voltage for Lamp-type alternators must set as follows: for 12V alternators -
in the range from 14 to 14.8 volts, for 48V alternators – from 28 to 29.8 volts.
4.2 The stabilizing voltage for alternators of C JAPAN type must set in the range from 14 to
14.5 volts.
5*. Change the stabilizing voltage in the range from 13.2 to 14.8 volts. The measured voltage must
vary in proportion.
* This does not apply to Lamp-type alternators.
5.1 When testing alternators of C JAPAN type, switch the preset stabilizing voltage to OFF. The
measured stabilizing voltage must set in the range from 12 to 12.7 volts.
6. Set the alternator voltage in the range from 13.2 to 14.8 volts. For C JAPAN alternators, switch
the preset voltage to ON. Increase the engine crankshaft rotation speed to medium. The
measured voltage must not change (the deviation by ±0,2V, is within the norm).
7. Without reducing the engine crankshaft speed, increase the load on the alternator by
switching on headlights and other lights. The voltage must not change (the voltage can reduce
no more than by 0.3V from the preset one).
8. Stop the engine.
9. Disconnect the cable clips from the alternator.
10. Failure to perform as described in sub-items 2.1, 3-7 indicates the voltage regulator
malfunction.
WARNING!
Test alternators either outdoors or in premises equipped either with a supply-
and-extract ventilation or an exhaust system.
Summary of Contents for RTP9007S
Page 2: ......
Page 32: ...English tester RTP9007S 30 ...
Page 33: ...English Operation manual 31 ...
Page 34: ...English tester RTP9007S 32 APPENDIX 3 Connection of voltage regulators to the tester ...
Page 35: ...English Operation manual 33 ...
Page 36: ...English tester RTP9007S 34 ...
Page 37: ...English Operation manual 35 ...
Page 38: ...English tester RTP9007S 36 ...
Page 39: ...English Operation manual 37 ...
Page 40: ...English tester RTP9007S 38 ...
Page 41: ...English Operation manual 39 ...
Page 42: ......
Page 43: ......