![ARUSNAVI ELECTRONICS ARNAVI 5 User Manual Download Page 24](http://html1.mh-extra.com/html/arusnavi-electronics/arnavi-5/arnavi-5_user-manual_2979438024.webp)
USER MANUAL [1.4]
Page 24
For commands to control the outputs, refer to the section “SMS and TCP command list”.
‘Output mode 1’
– the normal operation mode of the output with saving the state in non-volatile
memory and recovery after restarting the device.
The output status is changed by a command from the server or SMS. The output is forcibly deactivated
when the operating mode is changed.
In Wialon system, output state is contained in parameter “pin”.
The state of the discrete inputs/outputs is transmitted bitwise in "pin" parameter. In binary form,
each bit of the "pin" parameter reflects the status of the corresponding input. For example, if value = 8 in
decimal, it means that IN_3 is activated and the others are deactivated.
You can request a communication protocol for details.
‘Reset Wi-Fi’
– the mode is used when using an external WI-FI module. Detailed description in
section "RS-232 interface" - WI-FI mode.
‘i-Button’
–
the mode is used to indicate the fact of reading any 1-Wire key. At moment of reading,
the output is activated for a few seconds, then deactivated. See "1-WIRE Interface" for more
information.