Port Specifications
Appendix A
16
Aruba AP 70
0510159-02
Installation Guide
September 2006
When the Aruba AP 70 is installed in an air-handling space, as described in NEC
(2002) Article 300.22 (C), POE is required. Also, any FE cable installed in such
spaces should be suitable under NEC Article 800.50 and marked accordingly for
use in plenums and air-handling spaces with regard to smoke propagation, such
as CL2-P, CL3-P, MPP or CMP.
Install cables in accordance with all applicable local regulations and practices.
Serial Breakout Adapter
The optional serial breakout adapter is used to separate the serial
communications lines from the Aruba AP 70 FE+SPOE port. This allows the
administrator to connect a local serial console directly to the AP and access the
apboot
prompt for manual provisioning.
The serial breakout adapter pin-outs are shown in
Figure A-2
:
F
IGURE
A-2
Aruba Serial Breakout Adapter
RJ-45 Male "To Network" Pin-Out
1
2
3
4
5
6
7
8
ETH Tx+
(POE
negative)
ETH Tx–
(POE
negative)
ETH Rx+
(POE
positive)
ETH Rx–
(POE
positive)
Serial TxD
Serial TGND
Serial RxD
Serial RGND
RJ-45 Male "To AP" Pin-Out
1
2
3
4
5
6
7
8
ETH Rx+
(POE
negative)
ETH Rx–
(POE
negative)
ETH Tx+
(POE
positive)
ETH Tx–
(POE
positive)
RxD
TxD
SG
5
4
3
2
1
9
8
7
6
DB-9 Female Pin-Out
Input
Output
Direction
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Internal Adapter Wiring
"To AP"
"To Network"
To Console