Procedure
1. Remove the AC power cable from the power supply’s connector.
2. Grasping the handle of the failed power supply, use the Release Latch to release the locking mechanism.
Figure 18: Replacing a failed power supply
1
2
Table 15: Replacing failed power supply: Label and description
Label
Description
1
Release latch
2
Power supply pull handle
3. Insert the new power supply. Slide it all the way in until the locking mechanism clicks into place.
4. Connect the AC power cable to the new power supply's connector
Replacing a fan tray
The Aruba 8360 switch is equipped with three field-replaceable, hot-swappable fan trays. The switch can
tolerate the failure of a single fan tray while maintaining a safe operating temperature. To maintain system
redundancy, a failed fan tray should be replaced as soon as possible. The Fan LED will FLASH amber,
indicating a fan tray has failed.
46
Aruba 8360 Switch Series Installation and Getting Started
Guide