PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
33
STATus: QUEStionable:EVENt
(query only)
Function:
Return and clear the contents of the QUEStionable register. The response
is a decimal value that summarizes the binary values of the set bits.
Syntax:
STATus:QUEStionable :EVENt?
Returns:
<NR1>
Examples :
STATus:QUEStionable :EVENt?
returns 0.
SYSTem:AUTO:CYCLe
Function:
Set or query the number of times of execution (The PSS and PSH series do not
have this function.)
Syntax:
SYSTem:AUTO:CYCLe <NR1>
SYSTem:AUTO:CYCLe ?
<NR1>
is in the range from 0 through 99999 or infinite.
Returns:
<NR1>
Examples :
SYSTem:AUTO:CYCLe 8
sets auto cycle on to repeat the setting 8
times.
SYSTem:AUTO:CYCLe 0
sets auto cycle on to repeat the setting
infinite.
If the command
SYSTem:AUTO:CYCLe?
Returns 0, means infinite.
PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
34
SYSTem :AUTO:DELay
Function:
Set the delay time under the current responding memory status
(The PSS
and PSH series do not have this function.)
Syntax:
SYSTem:AUTO:DELay <NR1>
SYSTem:AUTO:DELay ?
<NR1>
is in the range from 1 through 59999, its unit is 100ms.
Returns:
<NR1>
Examples :
SYSTem:AUTO:DELay 1
sets auto delay time at 100ms for the memory
of the specific section.
SYSTem:AUTO:DELay 1 000
sets auto delay time at 100 seconds for
the memory of the specifi c section, no further setting of auto delay will
be done on next memory section until the previous auto delay is fulfilled.
If the command
SYSTem :AUTO:DELay?
Returns 5, means delay
500ms at the current memory section that displayed on the LCD panel.
SYSTem :AUTO:END
Function:
Set the end memory section for auto execute continuously
(The PSS and
PSH series do not have this function.)
Syntax:
SYSTem:AUTO:END <NR1>
SYSTem:AUTO:END ?
<NR1>
is in the range from 0 through 99 and must be large or equal t o
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com