PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
21
Examples :
*IDN? Returns
GW, PST -3202, 0, FW:1.00
*OPC
Function:
The command form (
*OPC
) sets the operation complete bit (bit 0) in the
Standard Event Status Register (SESR) when all pending operations are
finished.
The query form (
*OPC?
) tells the programmable power supply to place
an ASCII 1 in the Output Queue when the power supply completes all
pending operations.
Syntax:
*OPC
*OPC?
Returns:
1
*RCL
Function:
Recall the setting data from the memory saved previously. (The PSS and
PSH series do not have this function)
Syntax:
*RCL <NR1 >
<NR1>
is in the range from 0 through 99.
Examples :
*RCL 12
recalls the setting data stored in memory location 12 .
PST & PSS & PSH SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
22
*RST
(no query form)
Function:
Set all control settings of power supply to their default values but does
not purge stored setting. The equivalent panel control will be set as
below :
Front Panel Control
Default Setting
OUTPUT
OFF
CURRENT SET
0
VOLTS SET
0
OCP SET
OFF
DELAY
1 sec
AUTO SET
OFF
RECALL (memory location) 00
OVP SET
MAXimum (Please refer to
the user manual for the OVP
setting)
OUTPUT MODE (INDEP/
SERIES/PARALLEL)
INDEP
STEP SET
MINIMUM (Please refer to
the user manual.)
RECALL RANGE
START 00 END 05
CYCLE 1
Syntax:
*RST