8
EFT/ Burst Generator PEFT Junior
2. Safety
2.1 Safety standards
The generator has been constructed in accordance with IEC 348 and IEC 1010: Safety
requirements for electronic apparatus.
This user manual contains information and warnings that must be heeded by the user for safe
and efficient use of the generator.
2.2 Environmental conditions
The generator contains high voltage circuits in a very small volume, this defines the
environmental conditions under which it may be operated.
Temperature
15 °C to 35 °C
Relative humidity
45 % to 75 %
Atmospheric pressure
86 kPa to 106 kPa
(860 to 1060 mbar)
Absence of
Frost, dew, rain,
condensation, water
infiltration, direct sun
Tab.
2.2
The generator must only be used in dry rooms. In the case of visible condensation, the generator
must be dried before use.
Under certain conditions sparks can be produced by the EUT or generator. Because of this the
generator must not be used in an area where an explosion hazard exists.
WARNING
Persons with heart pace makers must not be in
the area when the generator is operating