ARTEX PRODUCTS / ACR ELECTRONICS, INC
DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL
ME406 (453-6603), ME406HM (453-6604)
Page 59 of 72
Mar 19/15
25-62-30
SUBTASK 25-62-30-450-009
J.
Buzzer Connections
1)
Connect the power wire to the buzzer positive (+) terminal.
2)
Connect the ground wire to the buzzer negative (–) terminal.
SUBTASK 25-62-30-450-010
K.
Remote Switch Final Installation
1)
Insert the harness plug into the remote switch receptacle.
2)
Install the remote switch assembly in accordance with SUBTASK 25-62-30-450-001 on page 55.
TASK 25-62-30-410-801
7.
ELT Installation
SUBTASK 25-62-30-410-001
A.
Installation and Test
CAUTION: TAKE CARE TO KEEP THE REMOTE SWITCH PLUG STRAIGHT WHEN CONNECTING IT TO
THE ELT. IF THE PLUG IS COCKED (I.E., CROOKED) WHEN INSERTING IT INTO THE ELT
RECEPTACLE, THE ELT MAY ACTIVATE. IF THE ELT ACTIVATES, RESET IT BY CYCLING
THE LOCAL CONTROL SWITCH TO “ON” AND THEN BACK TO “ARM”.
1)
See Figure 23 ELT Installation Sequence.
Figure 23 ELT Installation Sequence
2)
Verify the ELT local switch is in the “ARM” position.
3)
Insert the ELT into the mounting tray at an angle, such that the locking ears at the end opposite the
direction-of-flight arrow fit into the mounting tray locking slots.
4)
Press the ELT down until it is fully seated in the mounting tray.