25-62-30
5-Flash
Indicates there is no navigation position data present (long message protocol only)
ELT programmed with a long message
format
Reprogram to short message or ignore
error code. 5 flash code does not indicate a
hard failure and does not affect
airworthiness of unit.
6-Flash
Indicates G-Switch loop between pins 5 and 12 is not present
Jumper open
Verify D-Sub connector jumper is installed
by checking for less than 1Ω between pins
5 and 12. Repair as necessary.
Jumper missing
Install D-Sub jumper between pins 5 and
12 in D-Sub connector.
7-Flash
Indicates a battery problem
Operating time is >1 hour
Replace battery pack
Electrical circuits faulty
Table 6 ELT Self-Test Error Codes Troubleshooting Guide