ELT Troubleshooting Guidelines
1)
Table 7 provides ELT troubleshooting guidelines for installation and operational issues.
SYMPTOM
PROBABLE CAUSE
POSSIBLE SOLUTION
Remote switch LED always on
(steady)
Improper wiring
Verify wiring
Short circuit
Check for frayed insulation
Verify LIGHT_ON wire. Check
continuity between pin 2 and pin 9
on remote switch harness
connector with ELT disconnected
from harness. If short to ground is
present, correct wiring short and
reinstall remote switch.
Remote Switch Faulty
Replace Remote Switch
ELT Faulty
Disconnect remote switch from
harness. Check continuity
between pin 2 and pin 9 on
remote switch harness connector
with ELT connected to harness. If
short to ground is present with
ELT deactivated, return ELT to an
Artex authorized repair facility.
ELT will not turn off
Battery too low to support 406
burst and causes circuit to reset
Remove battery pack to disable
ELT and replace battery pack
Turn off ELT using local switch - If ELT turns off:
Defective remote switch harness
reset circuit wiring
Check wiring continuity and repair
as necessary
Defective remote switch
Replace remote switch
If ELT does not turn off using local switch:
ELT defective
Remove battery pack to disable
ELT and return ELT to factory for
servicing
Table 7 ELT Troubleshooting Guide