Table 6 ELT Self-Test Error Codes Troubleshooting Guide
SUBTASK 25-62-11-810-002
B.
ELT Troubleshooting Guidelines
1)
Table 7 provides ELT troubleshooting guidelines for installation and operational issues.
SYMPTOM
PROBABLE CAUSE
POSSIBLE SOLUTION
Remote switch LED always on
(steady)
Improper wiring
Verify wiring
Short circuit
Check for frayed insulation
Verify integrity of all crimp and
solder connections
ELT will not turn off
Battery too low to support 406
burst and causes circuit to reset
Remove battery pack to disable
ELT and replace battery pack
Turn off ELT using local switch - If ELT turns off:
Defective remote switch harness
reset circuit wiring
Check wiring continuity and repair
as necessary
Defective remote switch
Replace remote switch
If ELT does not turn off using local switch:
ELT defective
Remove battery pack to disable
ELT and return ELT to factory for
servicing
Table 7 ELT Troubleshooting Guide