Memory Maps and Registers
MVME2502 Installation and Use (6806800R96D)
129
Prescaler Adjust = 256-(CLKIN/CLKOUT)
CLKIN is the input clock source in MHz, and CLKOUT is the desired output clock reference in
MHz.
The prescaler provides the clock required by each of the three times. The tick timers require a
1 MHz clock input. The input clock to the prescaler is 25 MHz. The default value is set for
0x00E7, which gives 1 MHz reference clock for 25 MHz input clock source.
5.6.2
Control Registers
Table 5-25 Prescaler Register
REG
Prescaler Register - 0xFFC80100
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Field
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
RSVD
Prescaler Register (8-bits)
OPER
R/W
RESET
0x00e7
Table 5-26 Control Registers
REG
Tick Timer 0 Control Register - 0xFFC80202
Tick Timer 1 Control Register - 0xFFC80302
Tick Timer 2 Control Register - 0xFFC80402
Bit
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
Field
RSVD
RSVD
RSVD
RSVD
RSVD
INTS
CINT
ENINT
OVF
RSVD
COVF
COC
ENC
OPER
R/W
RESET
0x0000
Summary of Contents for MVME2502
Page 1: ...MVME2502 Installation and Use P N 6806800R96D December 2014 ...
Page 12: ...MVME2502 Installation and Use 6806800R96D 12 List of Tables ...
Page 14: ...MVME2502 Installation and Use 6806800R96D 14 List of Figures ...
Page 20: ...MVME2502 Installation and Use 6806800R96D About this Manual 20 About this Manual ...
Page 30: ...MVME2502 Installation and Use 6806800R96D Sicherheitshinweise 30 ...
Page 52: ...Hardware Preparation and Installation MVME2502 Installation and Use 6806800R96D 52 ...
Page 108: ...Functional Description MVME2502 Installation and Use 6806800R96D 108 ...
Page 142: ...Boot System MVME2502 Installation and Use 6806800R96D 142 ...
Page 154: ...Programming Model MVME2502 Installation and Use 6806800R96D 154 ...
Page 162: ...Related Documentation MVME2502 Installation and Use 6806800R96D 162 ...
Page 163: ......