I
NSTALLATION
&
U
SERS
M
ANUAL
FIREPLACE
| SOL 60/70/80/90
22 |
Page
13.
T
ECHNICAL
S
PECIFICATIONS
TECHNICAL SPECIFICATIONS
UNITS
SOL 60
SOL 70
SOL 80
SOL 90
*Total heat output
Kcal/h
8600
10320
12040
13760
kW
10
12
14
16
Recommended hourly consumption of firewood
Kg/h
3.1
3.7
4.3
4.9
Efficiency
%
77
77
77
77
Exhausts temperature
°C
263
264
267
269
CO emissions
(by providing O
2
at 13%)
%
0.090
0.090
0.090
0.090
Yield range
(minimum - maximum)
kW
4.3 - 13.1
4.3 - 16.4
4.9 - 19.6
4.9 - 22.9
Fuel
-
Wood, Briquette
Device dimensions (W x D x H)
cm
59/50/55
69/50/55
79/50/55
89/50/55
Combustion chamber dimensions (W x D x H)
cm
42/27/37
52/27/37
62/27/37
72/27/37
Flue draft
Pa
12(±2)
Heated area
Kg/h
30 - 100
30 - 120
35 - 140
35 - 160
Weight
m
2
95
108
120
132
External air inlet.
The section must be increased by 20% for each
additional meter after 1 m
kg
Ø 10
Smoke outlet diameter
cm
Ø 15
Ø 18
**Minimum flue height
m
4
Minimum heating area
m
2
25
30
35
40
* The fireplace operates with intermittent combustion technology. In this case intermittent combustion means the normal use of the fireplace, e.g. new
firewood is added as soon as the previous are burned, forming a sufficient amount of cinder.
** The internal section of the flue must be increased by 10% per 500m altitude above sea level.
Table 13.1