In case of an inclined roof, the height of the chimney is defined depending on the inclination and the distance of the chimney from the
ridge according to the following table.
(Pic. 6.4.2.3)
Inclination
α
ο
RIDGE – CHIMNEY
DISTANCE
MIN HEIGHT
ABOVE THE RIDGE
Α
(m)
H (m)
15
ο
< 1,85 m
0,50 m OVER THE RIDGE
> 1,85 m
1,00 m OVER THE ROOF
30
ο
< 1,50 m
0,50 m OVER THE RIDGE
> 1,50 m
1,30 m OVER THE ROOF
45
ο
< 1,30 m
0,50 m OVER THE RIDGE
> 1,30 m
2,00 m OVER THE ROOF
60
ο
< 1,20 m
0,50 m OVER THE RIDGE
> 1,20 m
2,60 m OVER THE ROOF
Pic. 6.4.2.3
6.4.3.
Chimney cap
The chimney draft depends broadly on the adequacy of the cap.
So, in case the chimney is built, its exhaust diameter should be at least twice the inside diameter of the chimney. Knowing that it is necessary
to protrude from the ridge of the roof, the cap must ensure the proper smoke dissipation in case of strong wind.
A chimney cap must meet the following requirements:
Internal diameter must be equal to the diameter of the chimney.
Exhaust diameter be at least twice the inside diameter of the chimney.
It should be constructed in such a way as to avoid the entrance of rain, snow and any foreign body in the chimney
It can be checked, maintained and cleaned easily.
Industrial style cap with
protective net
Cap with deflector. It leans
according to the wind and it
provides very good smoke
dissipation.
Cap with fan. It provides
very good smoke
dissipation even in case
of weak winds.
Pic. 6.4.2.1
Pic. 6.4.2.2
Table 6.4.2.1