Keep  this  manual  for  the  safety  warnings  and  precautions,  assembly,  operating,  inspec-
tion, maintenance and cleaning procedures. Write the product’s serial number in the back 
of the manual near the assembly diagram (or month and year  of purchase if product has 
no number). Keep this manual and the receipt in a safe and dry place for future reference. 

 

GENERAL SAFETY RULES 

 

WARNING! Read all instructions Failure to follow all instructions listed below 
may result in serious injury. 

The term “vacuum chamber in all of the warnings 

listed below refers to your ArtMolds Vacuum Chamber. 

 

SAVE THESE INSTRUCTIONS

 

 
1. Work area safety

 

a. Keep work area clean and well lit. 

Cluttered or dark areas invite accidents.

 

b. 

Keep children and bystanders away while operating a vacuum chamber. 

Distractions can cause you to lose control.

 

2. Personal safety

 

a.  Stay alert, watch what you are doing and use common sense when operating a 

pneumatic tool. Do not use a vacuum chamber while you are tired or under the 

influence of drugs, alcohol or medication. 

A moment of inattention while operat-

ing pneumatic tools may result in serious personal injury.

 

b. 

Use safety equipment. Always wear eye protection. 

Safety equipment 

such as dust mask, work gloves, non-skid safety shoes, hard hat, or hear-

ing protection used for appropriate conditions will reduce personal inju-

ries.

 

c.  Dress properly. Do not wear loose clothing or jewelry. Keep your hair, clothing 

and gloves away from moving parts. 

Loose clothes, jewelry or long hair can be 

caught in moving parts.

 

d.  If devices are provided for the connection of chemical vapor extraction and col-

lection facilities, ensure these are connected and properly used. 

Use of these 

devices can reduce vapor-related hazards.

 

3. Vacuum Chamber use and care

 

a.  Do not over tighten the pneumatic fittings Use the correct tool for your applica-

tion. 

The correct tool will do the job better and safer at the rate for which it was 

designed.

 

b. 

Disconnect the vacuum chamber from the air source before making any 

adjustments, changing accessories, or storing. 

 

Summary of Contents for TPA2001R

Page 1: ...anual may not be drawn proportionally Due to continuing improvements actual product may differ from the product described herein Distributed exclusively by EnvironMolds LLC 18 Bank Street Summit NJ 07901 Visit our website www artmolds com Read this material before using this product Failure to do so can result in serious injury SAVE THIS MANUAL Copyright 2010 by EnvironMolds LLC All rights reserve...

Page 2: ... common sense when operating a pneumatic tool Do not use a vacuum chamber while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operat ing pneumatic tools may result in serious personal injury b Use safety equipment Always wear eye protection Safety equipment such as dust mask work gloves non skid safety shoes hard hat or hear ing protection used f...

Page 3: ...ing contact EnvironMolds LLC for a replacement 2 Avoid unintentional starting Prepare to begin work before turning on the tool 3 Do not leave the vacuum chamber unattended when a vacuum pump is operating Un plug it before leaving 4 This product is not a toy Keep it out of reach of children 5 People with pacemakers should consult their physician s before use Electromagnetic fields in close proximit...

Page 4: ...EQUIRED FOR ASSEMBLY Adjustable Wrench Petroleum Jelly ASSEMBLY STEPS 1 Thread the vacuum gauge onto the brass fitting that will attach to the vacuum chamber Use an adjustable wrench to tighten Do not over tighten Plumbers tape is not re quired 2 Take the assembled fitting with gauge and thread it into the side of the chamber Use an adjustable wrench to snug it up Do not over tighten Plumbers tape...

Page 5: ... text under subheadings therein before set up or use of this product General Operating Instructions NOTE While not required for operation it is advisable to mount a quick release air fitting to the Air Fitting This will make it eas ier to quickly attach and detach the vacuum hose from this tool This is available in the air tool section of home improvement and hardware stores 1 Mix your rubber acco...

Page 6: ...SE clean external surfaces of the tool with clean moist cloth PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE O...

Page 7: ...ber body 6 You can check for leak location using soapy water Vacuum level is low 1 Ensure that the air valve on the vacuum cham ber is completely closed 2 Ensure that a good clean seal is made be tween the housing the rubber gasket and the acrylic cover over vacuum chamber 3 Check for leaks Water in oil As the vacuum pump pulls moist air from the atmos phere some of the water vapor is deposited in...

Page 8: ...thin the vacuum pump That water needs to be drained through the valve usually located at the base of the vacuum pump See the pump manual LIMITED 90 DAY WARRANTY EnvironMolds LLC makes every effort to assure that its products meet high quality and durability standards and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days...

Reviews: