Summary of Contents for TECMount 274

Page 1: ......

Page 2: ...and SENSOR Switch 5 Technical Specifications 6 Wetted Materials 6 Thermal Performance Graph 7 Pressure Drop vs Flow Graph 8 Configuring the Temperature Controller 9 Using the Thermistor on Standard V...

Page 3: ...erformance a 5400 15 28 TECSource temperature controller is required The 274 TECMount also offers all the features you would expect from a modern diode fixture including Hard nickel over copper therma...

Page 4: ...when using the barbs pipe clamps be used to secure the hose to the 274 NOTE Earth Grounding Considerations If your application requires that the cold plate be earth grounded you should directly wire...

Page 5: ...ne polarity and pins 8 and 15 should be the opposite polarity If polarities are not matched the instrument will indicate a sensor error EXT Input and SENSOR Switch The 274 features a SENSOR switch to...

Page 6: ...Sensor Phoenix 2 Pin plug p n 1803578 Coolant Inlet Outlet 1 8 Female NPT with pre installed brass hose barbs 3 8 I D hose GENERAL Recommended Coolant Distilled Water Max Water Pressure psi 80 Max Ho...

Page 7: ...resents typical performance and will vary by flow rate and other conditions 0 20 40 60 80 100 120 140 160 180 200 220 240 260 0 20 40 60 80 100 120 140 160 180 200 220 240 Device Thermal Load Watts TE...

Page 8: ...op vs Flow Graph Graph represents typical performance and will vary by flow rate and other conditions 0 0 2 0 4 0 6 0 8 0 10 0 12 0 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 Pressure Drop psi Volume Flow Ra...

Page 9: ...mount Using the Thermistor on Standard Versions The 274 LaserMount is equipped with a 10k negative temperature coefficient NTC thermistor specifically the BetaTHERM 10K3A1 A thermistor works by trans...

Page 10: ...uired temperature range The typical setting is 100 A but your application will determine the actual needs The Steinhart Hart Equation As can be seen from the temperature versus resistance graph above...

Page 11: ...case with the RTD used in the 274 of the RTD the following equation is used 1 2 0 BT AT R R Below R0 an additional term is added to the equation 100 1 3 2 0 T T C BT AT R R In both of these equations...

Page 12: ...e RTD and eliminate the cable or connector resistances When using 4 wire measurement mode you must select RTD 4 wire as the sensor type and then connect the Sensor and Remote Sensor at one side of the...

Page 13: ...will be voltage limited when controlling the mount To gain the maximum performance of the 274 150 the recommended controller is a 5300 10 18 which has an 10A 18V output or the 5400 15 28 which has a...

Page 14: ...Page 14 274 TECMount User s Manual Mechanical Drawings Top View Rear View...

Page 15: ...274 TECMount User s Manual Page 15 Top View Mount Plate on Front Rear View Mount Plate on Front Side View Mount Plate on Front...

Page 16: ...Page 16 274 TECMount User s Manual Optional Adapter Plates 3 2 Adapter Plate Top View 4 2 Adapter Plate Top View p n AP 01 3 2 p n AP 01 4 2 5 2 Adapter Plate Top View p n AP 01 5 2...

Page 17: ...274 TECMount User s Manual Page 17 274 with Adapter Plate Side View 274 Isometric View...

Page 18: ...oyo Instruments s option THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE ARROYO INSTRUMENTS...

Page 19: ...274 TECMount User s Manual Page 19 NOTES...

Page 20: ...Page 20 274 TECMount User s Manual Copyright 2016 Arroyo Instruments All Rights Reserved P N 530 1042 Rev E...