9.2
Selecting
Position
will open up a submenu for:
Deadband, Sensitivity, Filter, Ramp
and
Ramp Mode
.
9.3
Deadband
Selecting
Deadband
opens a new touchscreen
slider that allows to change the
Deadband
values on the selected axis.
Deadband
sets the starting point of the control.
This value defines when the setpoint will react
after the control was changed.
NOTE
If the
DRW-1
wheels is used as a controller,
Deadband
shall be set to
0
!
Otherwise there would be a
delay
in response!
9.4
Sensitivity
Selecting
Sensitivity
will open a new touchscreen
slider that allows you to change the sensitivity of the
control device for the selected axis
.
NOTE
Redo the procedure for the other axes and press
OK.
9.5
Filter
Additional low pass filter function for encoder
based controllers, like the DRW-1.
When the DRW-1 is used in a car or a train,
vibrations of the vehicle may be transmitted to
the DRW-1's encoders.
This can lead to irritations in the pan and tilt axis.
In case of such irritations, the operator can use
the
Filter
function to set a low-pass filter value,
which allows to
eliminate
these disturbing vibrations.
NOTE
A
too high Filter value
may cause a
delay
in
response.
Remote Control Setup