8.4
Speed
setup in
Angle Mode
NOTE
In order to operate the DRW-1 correctly in
Angle Mode
,
the following settings shall be made:
• Speed
100
• SENSITIVITY set to
0
• DEADBAND
set to
0
• RAMP
set to
0
• Ratio
set to
0
In the factory preset setup, the
Speed
is
assigned to the knobs K1, K2 and K3.
NOTE
In order to achieve a faster movement in
Angle Mode
, the
Ratio
values must be adjusted.
See page 12.
8.5
Speed
setup in
Speed Mode
NOTE
In order to operate the DRW-1 correctly in
Speed Mode
,
the following settings shall be made
:
Speed
01 - 100
•
SENSITIVITY set to
0
•
DEADBAND
set to
0
•
RAMP
set to
0
•
Ratio
set to
0
A
lower
Speed value will
under crank
the movement
of the remote head.
A
higher
Speed value will
over crank
the movement
of the remote head.
8.6
Ramp (K4, K5, K6)
In the factory preset setup, ramp is assigned to the knobs K4, K5 and K6.
Initially, ramp should be set to
0
.
NOTE
A high positive ramp value will delay the
response of the remote head!
The DEH-1will start and stop progressively
softer as the value increases.
NOTE
By unassigning K4. K5. K6 you can set individual
ramp values for start and stop for each axis.
The setting is then made via the touchscreen, by Selecting
Menu
,
Controls
,
Position
,
Ramp
Start
and
Ramp
Stop
.
Remote Control Setup
11
100
100