background image

KW8

Ver. 1.2

6

WARNING

• 

 Refer all servicing to qualified service personnel.  Servicing is required when the apparatus has 
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled 
or objects have fallen into the apparatus, has been exposed to rain or moisture, does not operate 
normally, or has been dropped.

• 

Since the device is a CLASS I apparatus, it must be connected only using an AC three-wire 

    grouding outlet.  If your outlet isn’t grouded, contact a liscensed electrician to replace it with a 
    property grounded outlet.

• 

 To reduce the 

risk of electric shock

, unplug the AC mains connector before installing audio cable. 

Reconnect the power cord only after making all signal connections. Do not use the product if the 
power cord is broken or frayed. Protect the power cord from being walked upon or pinched. 

• 

 To completely disconnect this apparatus from the AC mains, disconnect the power supply cord 
plug from the AC receptacle.

• 

 Avoiding hearing damage

. Professional loudspeakers are capable of producing extremely high 

sound levels and should be used carefully. Never stand close to loudspeakers driven at high 
volume. Set the volume to a safe level. You can adapt to a higher volume of sound that over time 
may sound normal but can be damaging to your hearing. Hearing loss worsens after exposure to 
a sound level of 90 dB or over for an extended period of time. If you experience ringing in your 
ears or muffled speech, stop listening and have your hearing checked. The louder the volume, the 
less time is required before your hearing could be affected.

• 

 Voltage  requirement

. Make sure that the supplied voltage stays within the specified range. Verify 

that your mains power connection satisfies the power ratings of the device.

• 

Only connect the power supply to an appropriate power outlet.

• 

Do not install the device in wet or humid locations without using weather protection.

• 

 TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not expose this apparatus to rain or 
moisture and objects filled with liquids, such as vases, should not be placed on this apparatus.

• 

The main plug of the power supply cord shall remain readily accessible.

CAUTION

• 

 Choking  Hazards

. This device contains small parts, which may present a choking hazard to small 

children. Keep the device and its accessories away from small children.

• 

It is important that loudspeaker systems are used in a safe manner.

• 

 Do not make repairs yourself

. Do not open the device, it contains potentially hazardous voltage 

and  there is risk of electrical shock. Never attempt to disassemble, repair or modify the system 
yourself. Disassembling the unit may cause damage that is not covered under the warranty. The 
device contains no user-serviceable parts. 

Repairs should only be performed by factory-trained 

service personnel.

 Do not plug the power cord in if you suspect that your device needs service or 

repair.

Summary of Contents for KW8

Page 1: ...KW8 Ver 1 2 KW8 USER GUIDE English...

Page 2: ...Product Overview 8 6 1 MOVEMENT 8 7 CONNECTING THE UNIT 9 7 1 BACK PANEL CONNECTORS 9 7 2 MAINS POWER CONNECTION voltage selector 9 7 3 AUDIO CONNECTION 11 7 4 DMX CONNECTION 11 7 5 VIDEO CONNECTION...

Page 3: ...the respective country specific regulations Waste Electrical and Electronic Equipment WEEE Please dispose of this product at the end of its operational lifetime by bringing it to your local collectio...

Page 4: ...the flexibility of the Owl will offer an almost limitless number of solutions and in some cases reduce the amount of speakers required for an installation The Owl is part of K array s portfolio of co...

Page 5: ...s such as radiators heat registers stoves or other apparatus including amplifiers that produce heat Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two bl...

Page 6: ...evel of 90 dB or over for an extended period of time If you experience ringing in your ears or muffled speech stop listening and have your hearing checked The louder the volume the less time is requir...

Page 7: ...external heat source such as a hair dryer Carrying handling and installing the device The device contains sensitive components Do not drop disassemble open crush bend deform puncture shred incinerate...

Page 8: ...KW8 Ver 1 2 8 Weight 10 kg 22 1 lbs 6 Product Overview 6 1 MOVEMENT 180 540 WARNING Do not obstruct the path of the speaker s movement...

Page 9: ...cted audio equipment mixing consoles processors etc must be connected to the AC power distribution in a proper way preserving AC line polarity and ground connection such that all grounding points are...

Page 10: ...ted to 230 VAC mains power To use the device on 115 VAC of mains power you will need to move the voltage selector to the correct value before connecting The voltage selector is located at the bottom o...

Page 11: ...next unit by connecting the AUDIO OUT plug on the first unit to the AUDIO IN plug of the second one 7 4 DMX CONNECTION The unit operates using the digital DMX 512 1990 signal Connection between the co...

Page 12: ...or must be plugged into the last unit DMX OUT panel connector of the DMX line 7 5 VIDEO CONNECTION The K OWL features a HD SDI camera supporting multiple output formats As default the camera outputs a...

Page 13: ...A023 K OWL 4 A034 K OWL A just add 11 to the previous address To select the addresses proceed as follow 1 Press the UP DOWN key until you reach the required DMX channel The numbers on the display will...

Page 14: ...ble time reaction to DMX signal fast to slow 248 255 Slow reaction time to DMX signal 6 Volume 0 255 Volume 0 dB to 7 Coverage 0 Wide coverage 255 Narrow coverage 8 Delay 0 Delay 0 ms 13 Delay 1 ms 24...

Page 15: ...picture below two different orientations are available The supporting structure from which the unit is hung must be capable of bearing the weight of the unit and must be sufficiently rigid so that it...

Page 16: ...the unit in for service In this instance you will be provided with an RA Return Authorization number which should be included on all shipping documents and correspondence regarding the repair Shipping...

Page 17: ...kHz 3 dB for 1W 8 Damping factor 100 Hz 500 THD N 1kHz 1 W 0 010 AC POWER Connector 1 x PowerCon Nominal voltage 115 230 Vac Operating Range 85 130 Vac 60Hz 190 240 Vac 50Hz I Nom 2 A at 115 Vac 1 A a...

Reviews: