C
hapter
Ⅲ
G
eneral
D
escriptions
for
F
unction
B
locks
Notes:
MO: Monday MO-SU: every day from Monday to Sunday
TU: Tuesday MO-TH: every day from Monday to Thursday
WE: Wednesday MO-FR: every day from Monday to Friday
TH: Thursday MO-SA: every day from Monday to Saturday
FR: Friday FR-SU: every day from Friday to Saturday
SA: Saturday SA-SU: every day from Saturday to Sunday
SU: Sunday
In case only OFF time is set, e.g. it is set to be OFF at 5:00 from Monday to
Thursday, and the FAB will turn OFF the output after 5:00 every day from MO
to TH. As for the ON time, it depends on other factors (The original status will
be maintained on Friday, Saturday and Sunday).
No matter which system is selected, the time intervals of the same day should
be arranged in a chronological order, for example:
May 1st, 2000 9:00 ON
11:00 OFF Q1 (OK)
12:00 ON
17:00 OFF
May 1st, 2000 9:00 ON
11:00 OFF Q1 (ERROR)
8:00 ON
8:30 OFF
MO 9:00 ON
11:00 OFF
15:00 ON
18:00 OFF
MO
SU
29
5.
Q1 (OK)
D/W
M00
8:00
24:00
D/W
24:00
5:00
M00
Q1
M00
Summary of Contents for AF-10MR-A
Page 1: ......
Page 25: ...Chapter II Installation and Wiring MEMO 15...
Page 75: ...Chapter Programming on FAB panel MEMO 65...
Page 94: ...FAB Intelligent Controllerr 84...
Page 106: ...FAB Intelligent Controllerr 96 MEMO...
Page 122: ......