TOP-PAD-IP2 DESKTOP INTERCOM STATION
User Manual
page 14/64
armtel.com
© Armtel
1.1.4.6 When TOP-PAD-IP2 is equipped with TOP-HS-IP2 Handset unit, they are
connected to the Desktop intercom station by cables of additional modules provided in
. The analogue path of the Handset unit is connected to RJ-22
socket, the digital path - to RJ-25 socket.
1.1.4.7 USB 2.0 socket (see
) is provided for connecting ADSL external adapter
in subsequent modifications of the Desktop intercom station for communication of
subscriber devices with ADSL interface included in IPN system.
1.1.4.8 Power supply of TOP-PAD-IP2
осуществляется
по
линии
РоЕ
is carried out via
PoE line in accordance with IEEE802.3at standard, and in the form of passive power over
twisted pair (passive PoE), without data transmission as well, when one port is transmitted
data, the second – power. If PoE injector is not available, an external 12 VDC power adapter
is provided.
1.1.4.9 When using the “Ethernet bonding” function, in addition to the main cable
Ethernet (Patch Cord) connected to RJ-45 socket on the base of TOP-PAD-IP2 enclosure, an
additional Patch Cord should be connected to another RJ-45 socket in accordance with
. Both cables are connected to the Ethernet switch. In this case, when configuring
TOP-PAD-IP2 in the IPN Config Tool, in the “Parameter” window in the “Working interfaces”
tab it is necessary to set the checkboxes for the ports “eth0” and “eth1” should be ticked. In
this way, the Ethernet channels are duplicated and automatically switched to the redundant
channel in the event of malfunction or failure in the primary channel of the Ethernet interface.
1.1.4.10 At the top of the front panel (above the display) there is a LED that indicates
the type of incoming or outgoing communication by solid light or blinking. In this iteration,
TOP-PAD-IP2 operates only one LED