DWEX DIGITAL LOUD-SPEAKING EXPLOSION PROOF CALL STATION
User Manual
armtel.com
page 15/40
© Armtel
Table 5 – DIP-switch positions
SWx.1
SWx.2
Type of installed module
OFF
OFF
Plug or dial pad (keypad
module)
ON
OFF
Two-way toggles for two
connections (including
buttons «SOS», «INFO»)
OFF
ON
Pushbuttons (8 direct keys
module)
ON
ON
Handset and a cradle
hermetic sensor
5 – «
R18
» – volume control of the main amplifier (VOLUME INT) – not used;
7 – «
R26
» microphone handset sensitivity control (MIC HS);
8 – «
R15
» built-in microphone sensitivity control (MIC INT);
9 – «
R22
» external microphone sensitivity control (MIC EXT) – not used;
11 – technological socket «
XP1
» for programming the board;
12 – switch «
SW2
» to select the type of microphone caps used in the remote
microphone:
1) in the ON position – electret microphone (remote with tangent);
2) in the OFF position, there is no dynamic microphone or microphone.
13 – socket «
X5
» for external microphone with tangent;
14 – switch «
SW1
» to select the type of microphone caps used in the front panel:
1) in the ON position – electret microphone (built-in);
2) in the OFF position, there is no dynamic microphone or microphone.
15 – socket «
X8
» for built-in speaker;
16 – socket «
X4
» for built-in microphone;
17 – switch «
SW3
» to select the type of microphone caps used in the handset:
1) in the ON position – electret microphone (tube);
2) in the OFF position, there is no dynamic microphone or microphone.