DCN-2 cable has the input («Alarm in») and output Alarm out») of alarm signaling.
«Alarm in» input is Х6 socket designed for connection of galvanically isolated relay
contacts from other devices (for example, the fuse boards, having such outputs), by which
the alarm signals from other devices of the communication system are transferred
to DCN-2.
The function of contacts for Х6 socket is given in Table А.4.
Table А.4 - Assignment of connector contacts Х6
Contact
Function
X6 connector appearance and
pin numbering
Х6:1
Input of an external alarm source signal
("dry contact")
Х6:2
«Alarm out» output (Х7 connector) – performs the error signaling of DCN-2 itself to
external circuits by galvanically isolated contacts of Р1 relay for the response of external
alarm devices (for example, the connection of external alarm beacon or horn).
The function of contacts for Х7 socket is given in Table А.5.
Table А.5 - Assignment of connector contacts Х7
Contact
Function
X7 connector appearance and
pin numbering
Х7:1
Normally closed contact
Х7:2
Common relay contact
Х7:3
Normally open contact
Relay P1 is triggered when an internal accident occurs together with the ERR 1 indicator