ACM-IP2 ANALOGUE SUBSYSTEMS MODULE
User Manual
armtel.com
page 5/28
© Armtel
ENG
Configuration of
АСМ
-IP2 is performed from the administrator's PC, on which
the "IPN2 Configuration Software" RU.RMLT.00041-01 should be installed.
Figure 1 shows several alternatives of
АСМ
-IP2 usage.
Figure 1 – Example of
АСМ
-IP2 operation within distributed intercom and alarm systems
For example, organization of simplex communication sessions on routes:
- DIS-IP2 – Ethernet interface – Fast Ethernet Switch – Ethernet interface –
АСМ
-IP2 –
AW call station;
- AW call station –
АСМ
-IP2 – USB interface – ADSL-IP2 – WI-Fi access point – Ethernet
interface – Fast Ethernet Switch – Ethernet interface – DIS-IP2;
- AW call station –
АСМ
-IP2 – USB interface – ADSL-IP2 – ADSL interface – DSLAM –
Ethernet interface – Fast Ethernet Switch – Ethernet interface – DW-IP2.
Organization of loud-speaking Public address / General alarm sessions on routes:
- DIS-IP2 – Ethernet interface – Fast Ethernet Switch – Ethernet interface –
АСМ
-IP2 –
external amplifier – 4x Relay modules – loudspeakers (up to 8 pcs.);
- AW call station –
АСМ
-IP2 – Ethernet interface – Fast Ethernet Switch – Ethernet
interface –
модуль
АСМ