ACM-IP2 ANALOGUE SUBSYSTEMS MODULE
User Manual
page 16/28
armtel.com
© Armtel
ENG
2.3.3 Installation of IP-address for ACM-IP2
During production, each ACM-IP2 is assigned the same default IP-address:
192.168.100.10, subnet mask: 255.255.255.0. Since units with the same IP-
addresses are not allowed on the same network, it is necessary to set the network parameters
for each ACM-IP2 before being connected to the network. To this end, you can use direct
connection of ACM-IP2 to the service computer. In this case, to power ACM-IP2, you should
use PoE injector or supply -48 V to "X21" socket from external DC power source.
Make records in the product passport about location and time of АСМ
-IP2 installation
and about IP-address installed.
2.3.4 Dismantling:
−
disconnect the interface cable from the RJ-45 socket;
−
disconnect the external power supply (if used);
−
disconnect the control lines with terminal units and the ADSL-IP2 Adapter (for
version RMLT.465275.006-01);
−
remove the
АСМ
-IP2 and the ADSL-IP2 Adapter (for version RMLT.465275.006-01)
from the DIN-rail;
−
pack
АСМ
-IP2 into the customer manufacturer’ package. If necessary, pack
АСМ
-IP2 into a shipping container.